Page view 8
8
Our broad-ranging output sphere
realizes high conversion eciency.
The result is highly ecient and
waste-free conversion of generated
electricity, even during low-sunlight
morning and evening hours or on
cloudy days.
8
MPPT* eciency 99.7%
Industry top-class Max. eciency of
96.2%, Euro. eciency of 95%
*Maximum Power Point Tracking
Triple combination achieving high eciency, high input voltage
and compact dimensions (low volume and weight) at the industry's cutting edge.
P
PP
V V
Maximum point (3000W)
Operation point
99.7%
Inverter eciency
96.2%
Operation point
95.0%
Inverter output
2877W
Inverter eciency
96.2%
Inverter output
2742W
Operation point
95.0%
Operation point
99.7%
Maximum point (3000W)
MPPT eciency of 99.7% MPPT eciency of 95.0%