Mitsubishi Electric DX-TL2500E User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
NETWORK PC SOFTWARE DX-PC25E
The machine can notify "Alarm" or "malfunction" to up to 5 e-mail
addresses. (through SMTP server)
Alarm Notification by e-mail
The machine notifies a networked PC.
When the PC receives an alarm or malfunction from the machine, Alarm
POP-UPs appear on the PC screen.
Alarm Notification
(
Resident software
)
* Screen shot reprinted with permission
from Microsoft Corporation.
DX-TL2500E
• The monitor screen can be switched between sequential
displays including full, quad, 9 or 16 split-screen mode.
• Two multiplexer outputs are supplied with this machine.
While displaying a split screen image to OUTPUT A, another
combination split screen can be displayed to OUTPUT B.
• Live picture from all cameras can be continualy recorded while
simultaneously playing back any desired camera picture
regardless of the monitor screen display.
* Local playback can not be done during network access to this machine.
• The picture of a specified camera can be recorded without
the image being displayed on the monitor screen.
• Picture from a particular camera can be displayed and not
recorded in instances where recording of the camera picture is
legally prohibited.
BUILT-IN DUPLEX 16CH MULTIPLEXER
50 pps capture rate makes it possible that 3 pps for all 16
cameras.
* Maximum 25pps/ch
Recording rate 50pps
Built-in one large capacity HDD,
3 built-in HDDs possible
Through SCSI interface, additional HDDS can be added
externally to give up to 12TB (2TB6ID) of memory
* Not all RAID systems are checked to work with the machine.
External Memory
Individual recording interval and picture grade for each camera
both in normal and alarm recording.
Various record setting for each camera
A wired remote control provides full
operation of the machine. In addition, it
can control dome cameras with full
functions in a very compact body.
Remote Controller
Wired Remote Control
RECORDING
Up to 16 dome cameras can be
connected with the machine. Even
different manufacturers' dome cameras
can be mixed and controlled individually
using an remote controller.
Dome Camera Control
EASE OF USE
After installed, powered on and setting clock / language, the
unit can be set up auto-matically: All connected camera
numbers are detected automatically and only by selecting
recording period, (24hr, 96hr, a week, a month, so on), the unit
assigns interval and picture grade for all cameras.
Auto Set-up
Digitally signed images can be exported through SCSI and
downloaded to an external CD-R/RW, DVD-RAM, MO, DDS2/3,
HDD or ZIP.
* External drive units are limited.
Archive / Copy
High activity detection is achieved by the detection area of 192
[12(V)16(H)] dots for efficient, prolonged recording by
detecting only the pictures that needed to be recorded.
Built-in Motion detection
Alarm images are recorded in a partition area to keep alarm images.
Alarm images can not be erased automatically in repeat rec. off mode.
The partition area can be set from 10% to 90% of HDD capacity.
Alarm Partition Recording
Achieve complete data redundancy by using the Mirror
Recording option.
Mirror Recording
Wavelet compression
1ch Audio recording
Image-alteration recognition function
• The image data in the digital recorder can be down-loaded
to a CompactFlash™ card and then played back by a PC.
• The contents such as menu setups can also be recorded in
a CompactFlash™ card so the data can be exchanged.
Multiple digital recorders can then be used under the same
setup conditions, with no need to set the digital recorders from
the beginning.
CompactFlash™ slot
A three-level password (Operator, Manager, Security Manager)
can be set up to limit access to settings and controls.
Password Lock
Full screen mode
4 split screen
mode
Start of alarm
recording
No motion detection points selected
Mitsubishi's unique motion-
detection preview screen
makes it easy to select the motion
sensitivity to suit the situation.
Detection area setting screen
Each point can be set to
for on and for off
Dome Camera
16
9 split screen
mode
16 split screen
mode
Very flexible and easy alarm recording setting can meet the
various demands of surveillance.
Easy setting
Both Normal and Alarm setting appears on the same screen.
• Flexible setting
3 kinds of Alarm Recording setting meet various alarm situations.
Alarm Recording
Pre-alarm recording duration can be set from 1 to 180 sec.
* Available Duration depends upon recording intervals and picture grade
Long Pre-alarm recroding up to 30 mins can be done,
when additional HDD (optional) is built-in.
Pre-alarm Recording
Alarm Channel
All recording capacity is changed to alarm recording.
Normal
Normal Recording
Up to 50pps
Alarm
Recording Only
up to 50pps
Alarm in
Alarm Plus
Alarm recording is done in addition to normal recording.
Alarm 25
Alarm recording can be done up to 25 pps by reducing normal
recording rate.
Normal
Normal Recording
Up to 50pps
Normal
Recording
Down to
25 pps
Alarm
Recording
Up to
25 pps
Total 50 pps Total 50 pps
Normal
Reserve
for
Alarm
Normal
Recording
Alarm
Recording
Normal
Recording
continues at
prealarm
rates
Alarm in
Alarm in
One large capacity HDD
is built-in. Additional 2
large capacity HDDs can
be added internally.
* Mitsubishi recommends
model names of HDD.
* The shaded HDDs are
optional.
OUTPUT BOUTPUT A
34
12
5
9
13
6
10
14
8
12
16
7
12 43
11
15
04-10-2003 00:42:00
04-10-2003 00:42:00
DX-TL2500E
SCSI
Up to 2TB/ID
0
2TB/ID1
2TB/ID2
2TB/ID3
2TB/ID4
2TB/ID5
TOTAL 12TB
*Maximum 25 pps/ch
Page view 1
1 2

Comments to this Manuals

No comments