Primary current protection
Secondary current protection
High-pressure protection
Defrosting in cooling
3 times
Lighting
Discharge temperature
protection
4 times
Lighting
Low discharge
temperature protection
• Check refrigerant circuit and refrigerant amount.
• Refer to 11-6. "Check of LEV".
• Refer to 11-6. "Check of outdoor thermistors".
• Refer to 11-6. "Check of LEV".
• Check refrigerant circuit and refrigerant amount.
5 times
Lighting
Cooling high-pressure
protection
This symptom does not mean any abnormality of the
product, but check the following points.
• Check indoor filters are not clogged.
• Check there is sufficient refrigerant.
• Check indoor/outdoor unit air circulation is not short cycling.
-
-
These symptoms do not mean any abnormality of the
product, but check the following points.
• Check indoor filters are not clogged.
• Check there is sufficient refrigerant.
• Check indoor/outdoor unit air circulation is not short cycling.
Twice Lighting
Once Lighting
The outdoor heat exchanger temperature exceeds 58°C during operation.
9 times
Lighting
Inverter check mode
Lighting
Lighting
Normal
The unit is operated with emergency operation switch.
-
The primary current exceeds 15 A (MXZ-3C54/3C68/4C71VA)/
17 A (MXZ-4C80VA)/18 A (MXZ-5C100VA).
The current of the compressor exceeds 12 A (MXZ-3C54/3C68/4C71VA)/
10 A (MXZ-4C80/5C100VA).
The indoor gas pipe temperature exceeds 45°C during heating.
The indoor gas pipe temperature falls 3°C or below during cooling.
The discharge temperature exceeds 100°C during operation.
The frequency of the compressor is kept 80 Hz or more and the discharge
temperature is kept under 50°C (cooling) /40°C (heating) for more than
40 minutes.
Outdoor electronic control P.C. board(Parts side)
LED2
LED1
Lighting
LED1
LED2
Lighting
MXZ-3C54/3C68/4C71VA
MXZ-4C80/5C100VA
LED1(Red) LED2(Yellow)
Abnormal point / Condition Remedy
Indication
Condition
No.
20
21
22
23
24
25
26
Outdoor unit
operates
normally.
Outdoor unit
operates.
Symptom
The flashing frequency shows the number of times the LED blinks after every 2.5-second OFF.
(Example) When the flashing frequency is “2”.
ON
OFF
2.5-second OFF
2.5-second OFF
0.5-second ON
0.5-second ON
NOTE 1. The location of LED is illustrated at the right figure. Refer to 11-7.1.
2. LED is lighted during normal operation.