Mitsubishi Electric PC36 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 55
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6/55
BCN-P5999-0113
1. OUTLINE
This manual explains the sample screens of GOT2000 connected to a MELSERVO-J3 Series (MR-J3-A)
servo amplifier in serial (RS-422) connection. The sample screens can be used for changing parameters,
monitoring, and conducting test operations.
2. SYSTEM CONFIGURATION
*1: The SD card is used for the logging and document display functions.
*2: The battery is used for the backup of the clock data and the logging data in the SRAM user area. (The
battery is provided with the GOT as standard.)
*3: For more details about the cable, please refer to the "GOT2000 Series Connection Manual (Mitsubishi
Products)".
3. GOT
3.1 System Applications That Are Automatically Selected
Type
System application name
Standard Function
Standard System Application
Standard Font
Japanese
Communication Driver
MELSERVO-J4, J3, J2S/M
Extended Function
Standard Font
Chinese (Simplified)
Outline Font
Gothic
Alphanumeric/Kana
Japanese (Kanji)
Chinese (Simplified)
Document Display
3.2 Controller Setting of Screen Design Software
Item
Set value
Remarks
Transmission Speed (BPS)
115200 bps
Data Bit
8 bit
Fixed
Stop Bit
1 bit
Fixed
Parity
Even
Fixed
Retry (Times)
3
Timeout Time (Sec)
3
Host Address
0
Station No. of servo amplifier configured in the system
Delay Time (ms)
0
Station No. Selection
Yes
Motor
MR-J3-A
Interface: RS-422 communication
connector (CN3)
RS-422 cable *3
GOT2000
GT27**-V (640×480)
Interface: Standard I/F (RS422/485)
SD card *1
Battery (GT11-50BAT) *2
Page view 5