Job Name: Location: Date:
Purchaser: Engineer:
Submitted to: For Reference Approval Construction
Unit Designation: Schedule No.:
Cooling*
Rated Capacity...............................24,000 Btu/h
Minimum Capacity
............................12,000 Btu/h
SEER
......................................16.8 Btu/h/W
Total Input
......................................2,340 W
Heating at 47°F*
Rated Capacity
...............................26,000 Btu/h
Minimum Capacity
............................12,000 Btu/h
HSPF (IV)
...................................10.9 Btu/h/W
Total Input
.......................................2,310 W
Heating at 17°F*
Rated Capacity
...............................18,000 Btu/h
Total Input
......................................2,220 W
* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB / 67ºF (19ºC) WB.
Outdoor: 95ºF (35ºC) DB / 75ºF (24ºC) WB.
(Heating) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 47ºF (8ºC) DB /
43ºF (6ºC) WB.
(Heating at 17ºF) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 17ºF
(-8ºC) DB / 15ºF (-9ºC) WB.
Electrical Requirements
Power Supply
....................208 / 230V, 1-Phase, 60 Hz
Breaker Size
........................................25 A
Voltage
Indoor - Outdoor S1-S2
......................AC 208 / 230V
Indoor - Outdoor S2-S3
............................DC 24V
Indoor - Remote Controller..........................DC 12V
OPERATING RANGE
Indoor Intake Air Temp. Outdoor Intake Air Temp.
Cooling
Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB 115ºF (46ºC) DB
Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB 0ºF** (-18ºC) DB
Heating
Maximum 80ºF (27ºC) DB, 67ºF (19ºC) WB 70ºF (21ºC) DB, 59ºF (15ºC) WB
Minimum 70ºF (21ºC) DB, 60ºF (16ºC) WB 12ºF (-11ºC) DB, 10ºF (-12ºC) WB
** With optional wind bafe accessory installed. If not installed, the minimum
temperature will be 23ºF (-5ºC) DB.
Indoor Unit: PCA-A24KA
Outdoor Unit: PUZ-A24NHA3
Indoor Unit
MCA .............................................. 1 A
Fan Motor
...................................0.54 F.L.A.
Fan Motor Output
...................................95 W
Airow (Lo - Mid1 - Mid2 - Hi)
..... 530 - 565 - 600 - 670 Dry CFM
495 - 530 - 565 - 635 Wet CFM
Air Filter ........................ Polypropylene Honeycomb
Sound Pressure Level (Lo - Mid1 - Mid2 - Hi)
.........33 - 35 - 37 - 40 dB(A)
DIMENSIONS UNIT INCHES / MM
W 50-3/8 / 1,280
D 26-3/4 / 680
H 9-1/16 / 230
Weight. ....................................71 lbs. / 32 kg
External Finish
....................Munsell No. 6.4Y 8.9 / 0.4
Field Drainpipe Size O.D.
....................1-1/16" / 26 mm
Wall-mounted Remote Controller.
................PAR-21MAA
(See Data Submittal Sheet)
Outdoor Unit
Compressor
..................DC Inverter-driven Twin Rotary
MCA
............................................ . 18 A
Fan Motor
....................................0.75 F.L.A.
Sound Pressure Level
Cooling
.................................... . .48 dB(A)
Heating
..................................... .50 dB(A)
DIMENSIONS INCHES / MM
W 37-3/8 / 950
D 13 + 1-3/16 / 330 + 30
H 37-1/8 / 943
Weight ...................................165 lbs. / 75 kg
External Finish
......................Munsell No. 3Y 7.8/ 1.1
Refrigerant Type
.................................. R410A
Refrigerant Pipe Size O.D.
Gas Side
................................5/8" / 15.88 mm
Liquid Side
................................3/8" / 9.52 mm
Max. Refrigerant Pipe Length
.....................165' / 50 m
Max. Refrigerant Pipe Height Difference
............100' / 30 m
Connection Method
................................Flared
SUBMITTAL DATA: PCA-A24KA & PUZ-A24NHA3 24,000 BTU/H CEILING-SUSPENDED HEAT-PUMP SYSTEM
Remote Controller:
PAR-21MAA
OPTIONAL ACCESSORIES
Indoor Unit
• External Heat Adapter (PAC-YU25HT)
• CN24 Relay Kit (CN24RELAY-KIT-CM)
• Condensate Pump (PAC-SH84DM-E)
• Remote Temperature Sensor (PAC-SE41TS-E)
• i-see Sensor (PAC-SH91MK-E)
• Wireless Remote Controller (PAR-FL32MA)
• Wireless Remote Control with Receiver Kit (PAR-SL93B-E)
• Wireless Remote Control with Receiver and i-see Sensor Kit
(PAR-SA92MW-E)
• High-efciency Filter (MERV 8) (PAC-SH89KF-E)
Outdoor Unit
• M-NET Adapter (PAC-SF80MA-E)
Air Outlet Guide (PAC-SG59SG-E)
• Wind Bafe (WB-PA2)
GENERAL FEATURES
• Ceiling-suspended indoor unit for residential and commercial
applications
• Shiny white cabinet; compact design
• Standard air lter is included with indoor unit; high-efciency
lter is available as an option
• Quiet operation—both indoor and outdoor units
• Optional Wireless Remote Controller with Receiver Kit is
available with or without i-see Sensor
• i-see Sensor available as a stand-alone option
• PAR-21MAA wired remote controller is included
• Self-check function—integrated diagnostics
• Limited warranty: ve years on parts and defects and seven years
on compressors
Page view 0
1 2 3

Summary of Contents

Page 1 - Purchaser: Engineer:

Job Name: Location: Date:Purchaser: Engineer:Submitted to: For Reference Approval ConstructionUnit Designation: Schedule No.:

Page 2 - Dimensions: PCA-A24KA

Dimensions: PCA-A24KA[ ]"ventilation air( )[ ]"[FRONT VIEWLOOKING THROUGH THE UNIT][BACK VIEW]If the piping is installed in the backof the u

Page 3 - Dimensions: PUZ-A24nHA3

3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecications are subjec

Comments to this Manuals

No comments