PERFORMANCE CURVES
Note : This diagram shows the case where the operation frequency of a compressor is fixed.
FOR THE COMBINATION OF OUTDOOR UNIT PUZ-HA·NHA2
1.4
1.2
1.0
0.8
72°F (22°C)
72°F (22°C)
68°F (20°C)
68°F (20°C)
64°F (18°C)
64°F (18°C)
61°F (16°C)
61°F (16°C)
90
(32°C)
70
(21°C)
50
(10°C)
30
(-1°C)
23
(-5°C)
110
(43°C)
1.2
1.0
0.8
0.6
0.4
INDOOR
W.B.
CAPACITY (RATIO)TOTAL INPUT (RATIO)
INDOOR
W.B.
OUTDOOR D.B.(°F)
Cooling performance curve