Mitsubishi Electric PKA-A12HAL Specifications Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
I
11"
Trouble Shooting
,:
,
:
Havinatrooble?
2<i
>i,,:'
....
Here'is the sollJtion}(Unlt'.isroperating normally;)
.•..
Airflow direction changes during operation or airflow direction cannot be
During cooling mode, the vanes automatically move to the horizontal
set.
(down) position after 1 hour when the down (horizontal) airflow direc-
tion
is
selected, This
is
to
prevent water from forming and dripping
from the vanes.
During heating mode, the vanes automatically move to the horizontal
airflow direction when the airflow temperature
is
low or during defrost-
ing mode.
When the airflow direction is changed, the vanes always move up and
When the airflow direction
is
changed, the vanes move to the set po-
down past the set position before finally stopping at the position.
sition after detecting the base position.
A flowing water sound or occasional hissing sound is heard.
These sounds can be heard when refrigerant is flowing in the air con-
ditioner or when the refrigerant flow
is
changing.
A cracking or creaking sound
is
heard.
These sounds can be heard when parts rub against each due to ex-
pansion and contraction from temperature changes.
The room has an unpleasant odor.
The indoor unit draws in air that contains gases produced from the
walls, carpeting, and furniture as well as odors trapped in clothing,
and then blows this air back into the room.
A white mist
or
vapor is emitted from the indoor unit.
If the indoor temperature and the humidity are high, this condition
may occur when operation starts.
During defrosting mode, cool airflow may blow down and appear like
a mist.
water
or vapor is emitted from the outdoor unit.
During cooling mode, water may form and drip from the cool pipes
and joints.
During heating mode, water may form and drip from the heat ex-
changer.
During defrosting mode, water
on
the heat eXchanger evaporates
and
water vapor may be emitted.
The ooeration indicator does not aopear
in
the remote controller display.
Tum
on
the
power switch.
"@"
will aooear in the remote controller
display.
"S' appears in the remote controller display.
During central control,
'S"
appears in the remote controller display
and air conditioner operation cannot be started or stopped using the
remote controller.
When restarting the air conditioner soon after stopping it, it does not
op-
wait
approximately three minutes.
erate even though the ON/OFF button is pressed. (Operation has stopped to protect the air conditioner.)
Air conditioner operates without the ON/OFF button being pressed.
Is the
on
timer set?
Press
the
ON/OFF button to stop operation.
Is the air conditioner connected to a central remote controller?
Consult
the
concerned people who control the air conditioner.
Does
'S"
appear in the remote controller display?
Consult the concerned people who control the air conditioner.
Has the auto recovery
feature from power failures been set?
Press the ON/OFF button to stop operation.
Air conditioner stops without the ON/OFF button being pressed.
Is the off timer set?
Press the ON/OFF button to restart operation.
Is the air conditioner connected to a central remote controller?
Consult the concerned people who control the air conditioner.
Does
W appear in the remote controller display?
Consult the concerned people who control the air conditioner.
Remote controller timer operation cannot be set.
Are timer settings invalid?
If
the timer can be set, ( WEEKLY), ( SIMPLE l, or
Qill!QOQEE)
appears
in
the remote controller display.
"PLEASE WAIT" appears in the remote controller display.
The initial settings are being performed.
wait
approximately 3 min-
utes.
An
error code appears
in
the remote controller display.
The protection devices have operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Tum off the power switch immediately and consult your dealer. Be
sure to provide the dealer with the model name and information that
appeared
in
the remote controller display.
Draining water or motor rotation sound is heard.
When cooling operation stops, the drain pump operates and then
stops.
wait
approximately 3 minutes.
Noise is louder than specifications.
The indoor operation sound level is affected
by
the acoustics of the
particular room as shown
in
the
follOWing
table and will
be
higher than
the noise specification, which was measured in an echo-free room.
High
sound-
Normal rooms
Low sound-ab-
absorbing
rooms
sorbing rooms
Location
Broadcasting Reception
Office, hotel
examples
studio, music room, hotel
room
room, etc.
lobby, etc.
Noise levels
3 to 7 dB
6t010dB
9 to 13 dB
Nothing appears in the wireless remote controller display, the display
The batteries are
low.
is
faint, or signals are not received
by
the indoor unit unless the remote Replace the batteries and press the Reset button.
controller is close.
If nothing appears even after the batteries are replaced, make sure
that the batteries are installed in the correct directions
(+,
-).
The operation lamp near the receiver for the wireless remote controller
The self diagnosis function
has
operated to protect the air conditioner.
on
the indoor unit is blinking.
Do not attempt to repair this equipment
by
yourself.
Tum off the power switch immediately and consult
your
dealer.
Be
sure to provide the dealer with the model name.
16
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 50 51

Comments to this Manuals

No comments