Mitsubishi Electric FR-E500 Instruction Manual

Browse online or download Instruction Manual for Power adapters & inverters Mitsubishi Electric FR-E500. Mitsubishi Electric FR-E500 Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 76
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
TRANSISTORIZED INVERTER
INSTRUCTION MANUAL
IB(NA)-66807-C(0212) MDOC Printed in Japan Specifications subject to change without notice.
HEAD OFFICE:MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100-8310
TRANSISTORIZED INVERTER
INSTRUCTION MANUAL
FR-PU04
Chapter 1
PRE-OPERATION
INFORMATION
Chapter 2
FUNCTIONS
Chapter 3
HELP
Chapter 4
OPERATION
Chapter 5
SPECIFICATION
FR-PU04
PARAMETER UNIT
STOP
RESET
12
3
456
789
0
EXT
PU
SETMON
ESCHELP SHIFT
FWD
REV
WRITE
READ
PARAMETER UNIT
STF FWD PU
FR-PU04
Page view 0
1 2 3 4 5 6 ... 75 76

Summary of Contents

Page 1 - INSTRUCTION MANUAL

TRANSISTORIZED INVERTERINSTRUCTION MANUALIB(NA)-66807-C(0212) MDOC Printed in Japan Specifications subject to change without notice.HEAD OFFICE:MITSUB

Page 2 - CAUTION

1.1 OverviewPRE-OPERATION INFORMATION11 PRE-OPERATION INFORMATION1.1 Overview1.1.1 Appearance and parts identificationUnpack the parameter unit from

Page 3 - Transportation and mounting

PRE-OPERATION INFORMATION2Key DescriptionWRITE key• Used to write a set value in the setting mode.• Used as a clear key in the all parameter clear or

Page 4

1.2 Installation and RemovalPRE-OPERATION INFORMATION31.2 Installation and RemovalTo ensure safety, install and remove the parameter unit after switc

Page 5 - - CONTENTS

PRE-OPERATION INFORMATION4 When connecting to the FR-S500/ F500J/ C500 series.1) Remove the front cover.2) Insert the cable plugs securely into the c

Page 6 - 3 HELP 32

1.3 Parameters to Be Checked FirstPRE-OPERATION INFORMATION51.3 Parameters to Be Checked FirstChange the following parameter settings as required.For

Page 7 - Contents

This chapter describes the "functions" for use of thisproduct.Always read the instructions before using the equipment.2.1 Monitoring Functio

Page 8 - 5 SPECIFICATION 61

2.1 Monitoring FunctionFUNCTIONS62 FUNCTIONS2.1 Monitoring Function2.1.1 Display overview120.00OLHzSTF FWD PU(2) PU level meter(1) Main monito

Page 9 - INFORMATION

FUNCTIONS7(5) Operation mode indicationDisplays the status of the operation mode.EXT : External operation modePU : PU operation modeEXTj : External jo

Page 10 - 1.1 Overview

FUNCTIONS82.1.2 Using the SHIFT key to change the main screenWhen "0" (factory setting) is set in Pr. 52 "PU main display data selectio

Page 11 - PRE-OPERATION INFORMATION

FUNCTIONS92.1.4 Using the HELP key to change the main screenA500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500CAUTIONThe functions vary with

Page 12 - 1.2 Installation and Removal

A - 1Thank you for choosing the Mitsubishi transistorized inverter option unit.This instruction manual gives handling information and precautions for

Page 13 - 1.2.2 Removal

FUNCTIONS10 When "current monitor" or "power monitor" is selectedNote that any current or power not more than 5% of the rated inve

Page 14

2.2 Frequency SettingFUNCTIONS112.2 Frequency SettingMake this setting in the PU operation mode.REMARKSThe external start signal (STF or STR) must not

Page 15 - FUNCTIONS

FUNCTIONS122.2.3 Precautions for frequency setting1) Pr. 79 "operation mode selection" must have been set to make the "PU operationmode

Page 16 - 2.1 Monitoring Function

2.3 Setting and Changing the Parameter ValuesFUNCTIONS132.3 Setting and Changing the Parameter ValuesThe inverter has a number of parameters. Using th

Page 17 - (7) Alarm indication

FUNCTIONS14POINTSet and/or change the parameter values in the PU operation mode. When the PUoperation indication is not shown, refer to page 54 and sw

Page 18 - 2.1.2 Using the

FUNCTIONS152.3.3 Function-by-function parameter settingA500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500You can set and/or change only the p

Page 19

FUNCTIONS162.3.4 User parameter registration and deletionA500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500Among all parameters, a total of 3

Page 20

FUNCTIONS17(2) Registration1) Press SET key.The parameter unit is put in the parameter settingmode.SETTING MODESet Pr. NOPr. Pr. List COPYHELP2)

Page 21 - 2.2 Frequency Setting

FUNCTIONS18(3) Deletion1) Press SET key.The parameter unit is put in the setting mode.SETTING MODESet Pr. NOPr. Pr. List COPYHELP2) Press READ k

Page 22

2.4 Calibration of the Meter (Frequency Meter)FUNCTIONS192.4 Calibration of the Meter (Frequency Meter)CAUTIONThe functions vary with the inverter. (R

Page 23 - 2.3.1 Direct setting

A - 2 SAFETY INSTRUCTIONS1. Electric Shock Prevention WARNING! Do not run the inverter with the front cover removed. Otherwise, you may accessexposed

Page 24 - 2.3.2 Step setting

FUNCTIONS202.4.2 Calibration of the AM terminalA500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500 This section provides a way to calibrate th

Page 25

FUNCTIONS21 Calibration procedure 2 (Example: Output current)To output the output current or another item which cannot easily achieve a 100% valueif o

Page 26 - (1) Confirmation

FUNCTIONS229) Press the SET key.The parameter unit is put in theparameter setting mode.SETTING MODESet <HELP>FOR PR. ListPr. NO.10) Type 1

Page 27 - (2) Registration

2.5 Adjustment of the frequency setting signals "bias" and "gain"FUNCTIONS232.5 Adjustment of the frequency setting signals "

Page 28 - <ESC>

FUNCTIONS24(1) Adjust only the bias and gain frequencies and not adjust the voltage Setting of the frequency setting voltage bias1) Press the PU key.T

Page 29

FUNCTIONS25 Setting of the frequency setting voltage gain7) Press the SHIFT key.The current Pr. 903 setting appears.Set 903 EXTVgain 60.00H

Page 30

FUNCTIONS26(2) Any point is adjusted with a voltage applied across terminals 2-5 Setting of the frequency setting voltage bias1) Press the PU key.The

Page 31

FUNCTIONS27(From the preceding page) Setting of the frequency setting voltage gain9) Press the SHIFT key, then theREAD key.The current Pr. 903 setting

Page 32

FUNCTIONS28(3) Any point is adjusted without a voltage applied across terminals 2-5 Setting of the frequency setting voltage bias1) Press the PU key.T

Page 33

FUNCTIONS29(From the preceding page) Setting of the frequency setting voltage gain9) Press the SHIFT key, then theREAD key.The current Pr. 903 setting

Page 34

A - 3(2) Test operation and adjustment CAUTION! Before starting operation, confirm and adjust the parameters. A failure to do somay cause some machine

Page 35

2.6 Copy and Verify FunctionsFUNCTIONS302.6 Copy and Verify Functions2.6.1 Copying the parameter settingsYou can read and store parameter settings int

Page 36

FUNCTIONS312.6.2 Verifying the parameters Verify1) Connect the FR-PU04 to the inverter.2) Press the SET key. This selects the setting mode.SETTING MOD

Page 37

This chapter explains the HELP key in the use of thisproduct.Always read the instructions before using the equipment.3.1 Overview of the Help Function

Page 38

3.1 Overview of the Help FunctionsH E L P323 HELP3.1 Overview of the Help FunctionsPress the HELP key twice in any operation mode to call the help fun

Page 39

H E L P333.1.2 Help function display dataCAUTIONThe functions vary with the inverter. keyHELPPress 1 MONITOR 2 PU Oper 3 Pr. List 4 Pr. Clear 5 A

Page 40 - 2.6 Copy and Verify Functions

H E L P34 1 Clear Pr. 2 Clear All 3 Clear User 4 Clear NonekeyPress twice. Clear Pr.ExecutingExec <Write>Cancel<ESC>Clear Pr.

Page 41

H E L P35<S/W> 1 M.Not Run 2 M.Spd Error 3 M.A/Dec Err 4 M.Curr.HighM.NOT RUNNINGMRS is ONM.SPEED ERRORSetF>MaxF1/F2 60. 00 HzPr1/18Stll P

Page 42 - CHAPTER 3

3.2 Operation Procedures for the Help FunctionsH E L P363.2 Operation Procedures for the Help FunctionsCAUTIONThe functions vary with the inverter.3.2

Page 43 - 3.1.1 Help function menu

H E L P37 To call the monitoring list directly in the monitoring mode1) Press the MON key.The parameter unit is put in the monitoring mode.(You need n

Page 44 - Pr.991

H E L P383.2.2 Selection of PU operation (direct input)You can select the PU operation mode via direct input (direct setting from the ten digitskey pa

Page 45

- CONTENTS -I1 PRE-OPERATION INFORMATION 11.1 Overview ...

Page 46

H E L P393.2.3 Selection of the PU jog operation modeA500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500(1) Calling from the help function men

Page 47 - 3.2.1 Monitor function

H E L P403.2.4 ParametersThe parameter menu is displayed and you can select and perform any of the followingoperations: Setting:...

Page 48

H E L P41(1) "2 Pr. List"1) Refer to page 40 and call the parameter menu. 1 SettingMODE 2 Pr. List 3 Set Pr. List 4 Def. Pr. List2)

Page 49

H E L P42(2) Display of "3 Set Pr. List"A500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500 When the parameter setting has been chan

Page 50

H E L P433.2.5 Parameter ClearThe parameter clear menu appears and you can select and perform any of thefollowing four operations:Switch to the PU ope

Page 51 - 3.2.4 Parameters

H E L P443.2.6 Alarm HistoryShows the history of eight past alarms. (*1)1) Press the HELP key twice in the operation mode.The help function menu is ca

Page 52 - (1) "2 Pr. List"

H E L P453.2.7 Alarm ClearClears all the alarm history.1) Press the HELP key twice in the operation mode.The help function menu is called. 1 MONITOR

Page 53

H E L P463.2.8 Inverter ResetResets the inverter.1) Press the HELP key twice in the operation mode.The help function menu is called. 1 MONITOR 2 P

Page 54 - 3.2.5 Parameter Clear

H E L P473.2.9 TroubleshootingA500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500If the inverter appears to operate improperly, perform the fo

Page 55 - 3.2.6 Alarm History

H E L P48(1) Troubleshooting guidanceM. NOT RUNNING ALARM Indicated <SHIFT>1) M.NOT RUNNING (Motor does not run)The inverter has alarm-tri

Page 56 - 3.2.7 Alarm Clear

II2.2 Frequency Setting ... 112.2.1 Direct setting ..

Page 57 - 3.2.8 Inverter Reset

H E L P49M. SPEED ERROR SetF>MaxF1/F2 60. 00 Hz Pr1/18Since the running frequency setting is higher than the maximum frequency (Pr. 1) setti

Page 58

H E L P504) M.Curr.HighInv. Output 60. 00Hz 10A 182. 4V <SHIFT>First, the running frequency,output current and output voltage of the inverter

Page 59 - (1) Troubleshooting guidance

H E L P513.2.10 SelectopA500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500Displays the signals assigned to the I/O terminals of the control c

Page 60 - 3) M.A/Dec Err

H E L P523.2.11 OptionDisplays what options are fitted to the option connectors.1) Press the HELP key twice in the operation mode.The help function me

Page 61 - 4) M.Curr.High

3.3 Other PrecautionsH E L P533.3 Other Precautions3.3.1 Precautions for parameter unit operationNote the following items when operating the parameter

Page 62

This chapter explains the basic "operation" for use of thisproduct.Always read the instructions before using the equipment.4.1 Operation Mod

Page 63 - 3.2.11 Option

4.1 Operation ModesOPERATION544 OPERATION4.1 Operation Modes4.1.1 How to select the operation mode(1) Switching from external operation mode [EXT] to

Page 64 - 3.3 Other Precautions

OPERATION55REMARKSIf the operation mode cannot be switched properly, check the following:1. External input signal...(STF

Page 65 - OPERATION

4.2 PU OperationOPERATION564.2 PU OperationCAUTIONThe functions vary with the inverter. (Refer to the inverter instruction manual for details.)4.2.1 O

Page 66 - 4.1 Operation Modes

OPERATION574.2.2 PU jog operationA500 F500 -NA -EC -CHE500 -NA -EC -CHS500 -CHF500J C500Hold down the FWD or REV key to perform operation, and rel

Page 67

III3.2.1 Monitor function... 363.2.2 Selection of PU o

Page 68 - 4.2 PU Operation

4.3 Combined Operation (Operation using external input signals and PU)OPERATION584.3 Combined Operation (Operation using external input signals and PU

Page 69 - 4. Operation

OPERATION594.3.2 Entering the running frequency from outside and making startand stop from the PU (Pr. 79 = 4)Step Operation Procedure Image1 Switch t

Page 70

OPERATION604.3.3 Entering the start signal and multi-speed signal from outsideand setting multiple speeds from the PUStep Operation Procedure Image1 S

Page 71

This chapter provides the "specifications" for use of thisproduct.Always read the instructions before using the equipment.5.1 Specifications

Page 72 - 4. Running frequency

5.1 SpecificationsSPECIFICATIONS615 SPECIFICATION5.1 Specifications5.1.1 Standard specificationsItem SpecificationsAmbient temperature -10°C to +50°C

Page 73 - SPECIFICATION

SPECIFICATIONS625.1.2 Outline drawing125 (4.92)72 (2.83)(0.59)(0.41)18.540 (1.57)80 (3.15)2413 (0.51)2021.5(0.85)14.548 (1.89)(0.97)(0.79)(0.73)(0.57)

Page 74 - 5.1 Specifications

REVISIONS*The manual number is given on the bottom left of the back cover.Print Date*Manual NumberRevisionOct., 1997 IB(NA)-066807-A First editionMar.

Page 75 - 5.1.3 Panel cutting drawing

IV4.2.1 Ordinary operation....... 564.2.2 PU jog operation A50

Page 76 - REVISIONS

This chapter provides the basic "pre-operation information(overview)" for use of this product.Always read the instructions before using the

Comments to this Manuals