Mitsubishi Electric FR-F720-00046 Instruction Manual

Browse online or download Instruction Manual for Power adapters & inverters Mitsubishi Electric FR-F720-00046. Mitsubishi Electric FR-F720-00046 Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 29
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION GUIDELINE
FR-F720-00046 to 04750-NA
FR-F740-00023 to 12120-NA
INVERTER
700
CONTENTS
INSTALLATION OF THE INVERTER AND INSTRUCTIONS................. 1
OUTLINE DRAWING............................................................................... 2
WIRING.................................................................................................... 4
PRECAUTIONS FOR USE OF THE INVERTER................................... 11
FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER ............ 12
PARAMETER LIST................................................................................ 13
TROUBLESHOOTING........................................................................... 19
Thank you for choosing this Mitsubishi Inverter.
Please read through this Installation Guideline and a CD-ROM enclosed to operate this inverter correctly.
Do not use this product until you have a full knowledge of the equipment, safety information and
instructions.
Please forward this Installation Guideline and the CD-ROM to the end user.
1
2
3
4
5
6
7
F700_kaigaidoukon_NA.book 1 ページ 2008年8月29日 金曜日 午後2時53分
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1 - INVERTER

INSTALLATION GUIDELINEFR-F720-00046 to 04750-NAFR-F740-00023 to 12120-NAINVERTER700CONTENTSINSTALLATION OF THE INVERTER AND INSTRUCTIONS...

Page 2

7WIRINGFR-F740-00770 to 01160-NA FR-F740-01800 to 02600-NAFR-F740-03250 to 04810-NA FR-F740-05470 to 12120-NACAUTION· The power supply cables must be

Page 3 - Environment

8WIRING(2) Cable sizeSelect the recommended cable size to ensure that a voltage drop will be 2% max.If the wiring distance is long between the inverte

Page 4 - FR --F740

9WIRING400V class (when input power supply is 440V based on the rated current for 110% overload for 1 minute)The line voltage drop can be calculated b

Page 5 - 2 OUTLINE DRAWING

10WIRING(3) Total wiring lengthThe overall wiring length for connection of a single motor or multiple motors should bewithin the value in the table be

Page 6 - OUTLINE DRAWING

11PRECAUTIONS FOR USE OF THE INVERTER4 PRECAUTIONS FOR USE OF THE INVERTERThe FR-F700 series is a highly reliable product, but incorrect peripheral ci

Page 7 - Control circuit

12FAILSAFE OF THE SYSTEM WHICHUSES THE INVERTER5 FAILSAFE OF THE SYSTEM WHICH USES THE INVERTERWhen a fault occurs, the inverter trips to output a fau

Page 8 - 3.1 Main circuit terminal

13PARAMETER LIST6 PARAMETER LIST6.1 Parameter listIn the initial setting, only the simple mode parameters are displayed.Set Pr. 160 User group read se

Page 9 - FR-F720-03160 to 04750-NA

14PARAMETER LIST33Frequency jump 2A0 to 400Hz, 9999999934Frequency jump 2B0 to 400Hz, 9999999935Frequency jump 3A0 to 400Hz, 9999999936Frequency jump

Page 10 - Screw size

15PARAMETER LIST118PU communication speed48, 96, 192, 384 192119PU communication stop bit length.0, 1, 10, 11 1120PU communication parity check0, 1, 2

Page 11 - (2) Cable size

16PARAMETER LIST168Parameter for manufacturer setting.Do not set.169170Cumulative power meter clear0, 10, 9999 9999171Operation hour meter clear0, 999

Page 12

F700_kaigaidoukon_NA.book 2 ページ 2008年8月29日 金曜日 午後2時53分

Page 13 - 3.2 Control circuit terminals

17PARAMETER LIST259Main circuit capacitor life measuring0, 1 0260PWM frequency automatic switchover0, 1 1261Power failure stop selection0, 1, 2 0262Su

Page 14

18PARAMETER LIST588Auxiliary motor 2 stopping frequency0 to 400Hz 0Hz589Auxiliary motor 3 stopping frequency0 to 400Hz 0Hz590Auxiliary motor start det

Page 15 - USES THE INVERTER

19TROUBLESHOOTING7 TROUBLESHOOTINGWhen a fault occurs in the inverter, the inverter trips and the PU display automatically changes to any of thefollow

Page 16 - 6 PARAMETER LIST

20TROUBLESHOOTING7.2 List of fault or alarm display* If an error occurs when using the FR-PU04, "Fault 14" is displayedon the FR-PU04.Operat

Page 17 - PARAMETER LIST

21(1) EMC DirectiveWe have self-confirmed our inverters as products compliant to the EMC Directive (second environment of conforming standard EN61800-

Page 18

22(Conforming standard UL 508C, CSA C22.2 No.14)(1) InstallationThis inverter is a UL / cUL Listed open type device for use inside an enclosure, or en

Page 19

23(2) Wiring of the power supply and motorFor wiring the input (R/L1, S/L2, T/L3) and output (U, V, W) terminals of the inverter, use the UL Listed co

Page 20

24MEMOF700_kaigaidoukon_NA.book 24 ページ 2008年8月29日 金曜日 午後2時53分

Page 21

25MEMOF700_kaigaidoukon_NA.book 25 ページ 2008年8月29日 金曜日 午後2時53分

Page 22 - 7 TROUBLESHOOTING

26REVISIONS*The manual number is given on the bottom left of the back cover. For Maximum Safety• Mitsubishi inverters are not designed or manufactured

Page 23 - TROUBLESHOOTING

A-14. Additional InstructionsAlso note the following points to prevent an accidental failure, injury, electric shock, etc.This section is specifically

Page 24 - Surrounding air

1INSTALLATION OF THE INVERTER AND INSTRUCTIONS1INSTALLATION OF THE INVERTER AND INSTRUCTIONS• Installation of the inverter • General PrecautionThe bus

Page 25 - Wiring protection

2OUTLINE DRAWING2 OUTLINE DRAWING• 200V class(Unit:mm(inches))Inverter Type W W1 H H1 DFR-F720-00046-NA110 (4.33) 95 (3.74)260 (10.24) 245 (9.65)110 (

Page 26 - (4) Motor overload protection

3OUTLINE DRAWING• 400V classInverter Type W W1 H H1 DFR-F740-00023-NA150 (5.91) 125 (4.92)260 (10.24) 245 (9.65)140 (5.51)FR-F740-00038-NAFR-F740-0005

Page 27

43WIRINGCAUTION• To prevent a malfunction due to noise, keep the signal cables more than 10cm away from the power cables. Also separatethe main circui

Page 28

5WIRING3.1 Main circuit terminal(1) Terminal layout and wiring200V classFR-F720-00046, 0007-NA FR-F720-00105 to 00250-NAFR-F720-00340, 00490NA FR-F720

Page 29 - FR-F740 - 04320 to 12120 - NA

6WIRING400V classFR-F720-03160 to 04750-NAFR-F740-00023, 00038, 00052, 00083, 00126-NA FR-F740-00170, 00250-NAFR-F740-00310, 00380-NA FR-F740-00470, 0

Comments to this Manuals

No comments