Page view 22
Mitsubishi Electric Automation | Variable Frequency Drives 359
F700 Series Options
Conduit Attachments
Instruction Manuals
Option Cards
External Heatsink Attachment
Model Number Description
Stocked
Item
FR-CB201 Extension cable straight plugs on both ends - 1 meter S
FR-CB203 Extension cable straight plugs on both ends - 3 meters S
FR-CB205 Extension cable straight plugs on both ends - 5 meters S
FR-DU07 Control Panel for F700 S
FR-PU07
LCD Multi-lingual Parameter Copy Unit (English,
French, Spanish, German, Italian, Swedish, Finnish,
Japanese) for operator control, parameter read/write and
monitoring. Stores
settings in non-volatile memory. Built-
in parameter copy capability. (F/A700 based)
S
FR-PU07-01 PU07 with hand/auto and enhanced display functions S
FR-ADP FR-DU07 panel mounting adapter S
FR-PU04
LCD Multi-lingual Parameter Copy Unit (English, French,
Spanish, German, Italian, Swedish, Finnish, Japanese) for
operator control, parameter read/write and monitoring.
S
SC-FRPC Serial Communication Cable S
FR-PU07BB-L Battery Powered PU07 S
FR-RJ45-HUB4 Serial Network Hub - 2 Stations -
FR-RJ45-HUB10 Serial Network Hub - 8 Stations -
FR-RJ45-TR Terminating Resistor for FR-RJ45-HUB -
Notes:
1. For FR-F700s smaller than listed above, they are UL Type 1, and conduit attachment is standard.
2. Mounting hardware included for standard DC chokes which ship with VFD. Kits are powder coated
similar to VFD, charcoal gray.
3. Kits are coated zinc clear.
4. Width and depth of kit match the asscociated VFD.
Note:
1. Kits are coated zinc clear.
Model Number
(*1)
Drive Model
Stocked Item
F720 F740
FR-A7CN01 00105 to 00250 00023 to 00126 S
FR-A7CN02 00340, 00490 00170, 00250 S
FR-A7CN03 00630 00310, 00380 S
FR-A7CN04 00770 to 01250 00470, 00620 S
FR-A7CN05 01540 - S
FR-A7CN06 - 00770 S
FR-A7CN07 01870, 02330 00930, 01160, 01800 S
FR-A7CN08 - 02160 -
FR-A7CN09 - 02600 -
FR-A7CN10 03160, 03800, 04750 03250, 03610 -
Manuals available for download at www.meau.com
Description Model Number
Stocked
Item
FR-F700 Installation Manual - Contains instructions
for installer and parameter list. (Included with VFD,
plus CD with all versions of VFD and option manu-
als.)
IB(NA)0600218 -
FR-F700 Basic Manual - Contains wiring details, VFD
layout drawings, alarm definitions and parameter
list.
IB(NA)0600216 -
FR-F700 Applied Manual - Contains wiring details,
VFD layout drawings, alarm definitions and complete
parameter list with definitions and setting examples.
IB(NA)0600217 -
FR-PU07 Manual - Contains complete instruction
sets and screen definitions.
IB(NA)0600240 -
Software
Model Number Description Stocked Item
FR-CONFIGURATOR
Programming and diagnostic
software
S
Model Number
Drive Model
Length
(in) (*4)
Weight
(lbs)
Stocked
Item
F720 (*1) F740 (*1)
FR-A7FN05 (*3) 01250 - 5.9" 5 -
FR-A7FN06 (*3) 01540 00770 6.2" 5 S
FR-A7FN07 (*3) 01870, 02330 00930, 01160 9" 15 S
FR-A7FN-10 (*2) - 01800 24" 37 S
FR-A7FN-11 (*2) - 02160, 02600 24" 41 S
FR-A7FN-12 (*2)
03160, 03800,
04750
03250, 03610 24" 45 S
FR-A7FN-13 (*2) - 04320, 04810 26" 50 S
FR-A7FN-14 (*2) -
05470, 06100,
06830
26" 64 S
Model No. Stocked Item
Function
Relay Output FR-A7AR S
12 Bit Digital Input FR-A7AX S
Digital Output
FR-A7AY S
Ext. Analog Output
BiPolar Analog Input
FR-A7AZ -High Res Analog Input
Motor Thermistor
Communication
CC-Link FR-A7NC S
DeviceNet FR-A7ND S
LonWorks FR-A7NL S
Profibus DP FR-A7NP S
Model Number Description
Stocked
Item
VFD-F700-DEMO-2
Includes F720 1HP, pre-wired digital input switches,
LED outputs, speed potentiometer and analog meter
S
VFD-MOTOR-DEMO
Includes 1/2HP motor with quick connection to
VFD-F700-DEMO
S
F700 Demonstration Unit
Parameter Units / Parameter Copy Units
Parameter units are used for operator control, reading and
writing parameters, and drive monitoring. Parameter Copy
Units also read the drive parameter settings and copy them into
non-volatile memory, and can write them into other drives.
Building Management Options
Notes:
1. For additional information, visit www.iccdesigns.com
2. Physically mounts within VFD and powered by VFD
3. Deep control cover is required
4. FR-E7TR option recommended. (PU connector not available for use)
5. Communication to multiple VFD’s is possible
6. Mounted and powered external to VFD
Network Type / Model
FR-A7N-ETH
(*2,*3,*4)
FR-A7N-XLT
(*2,*3,*4)
ETH-1000
(*5,*6)
XLTR-1000
(*5,*6)
Gateway
Communication
BACnet/IP X - X -
Ethernet/IP X - X -
Modbus/TCP X - X -
Profinet IO X - X -
BACnet MS/TP - X X X
Metasys N2 - X X X
Siemens FLN - X - -
Stocked Item S S - -
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 61 62

Comments to this Manuals