Mitsubishi-electric PFD-P250 • 500VM-A User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
GB
D
F
INL
E
PGRRUTR
3.2. Selecting operation
When selecting operation
1. Press the
33
33
3 [selecting operation] button
Consecutive press of the selecting operation button switches the operation
over to E
, , , ( ), and ( ). For the contents of operation,
check the display.
For cooling
Press the
33
33
3 [selecting operation] button and bring up the display.
For dry
Press the
33
33
3 [selecting operation] button and bring up the display.
The indoor fan turns to the low-speed operation, disabling the change of fan
speed.
Dry operation cannot be carried out at a room temperature of less than 18 °C.
For fan
Press the
33
33
3 [selecting operation] button and bring up the display.
The fan operation functions to circulate the air in the room.
The temperature of the room cannot be set by fan operation.
Caution:
Never expose your body directly to cool air for a long time. Excessive expo-
sure to cool air is bad for your health, and should therefore be avoided.
Dry operation
The dry is a microcomputer-controlled dehumidifying operation which controls ex-
cessive air-cooling according to the room temperature of your choice. (Not usable
for heating.)
1. Until reaching room temperature of your choice
The compressor and indoor fan function is linked motion according to the change
of the room temperature and automatically repeat ON/OFF.
2. When reaching room temperature of your choice
Both the compressor and indoor fan stop.
When stop continues for 10 minutes, the compressor and indoor fan are oper-
ated for 3 minutes to keep the humidity low.
Caution:
When the unit is used together with burners, thoroughly ventilate the
area. Insufficient ventilation can result in accidents due to oxygen defi-
ciency.
Never place a burner at a place where it is exposed to the airflow from the
unit.
Doing so can result in imperfect combustion of the burner.
The microcomputer functions in the following cases:
The fan is not moving at the set speed.
- In some models, the system switches over to faint airflow when the tempera-
ture of the room reaches the set temperature. In other cases, it stops to
prevent any cool air from escaping during the defrosting operation.
3.3. Room temperature adjustment
To change room temperature
Press the
11
11
1 [room temperature adjustment] button and set the room tem-
perature of your choice.
Pressing
or once changes the setting by 1 °C.
If the pressing is continued, the setting continues to change by 1 °C.
Indoor temperature can be set within the following range.
Cooling/dry: 14 - 30 °C
It is impossible to set the room temperature by the air-blow operation.
* The range of room temperature display is 8 - 39 °C. Outside this range, the
display flashes either 8 - 39 °C to inform you if the room temperature is lower or
higher than the displayed temperature.
3.4. Time setting
Set the current time after turning ON the power of the unit or after restoration
from a power failure.
It can be set regardless of the operation of the indoor unit.
During the time operation, the time-setting button becomes void, disabling time
setting.
1. Press the
44
44
4 [time selection] button and bring up the
AA
AA
A current time
display
Every time it is pressed, the display changes.
CLOCK
current
time
(no display)
timer end
time
OFF
timer start
time
ON
Caution:
When the current time is not yet set, the CLOCK (current time) display
flashes, disabling the setting of timer operation.
2. Set the current time by pressing the
44
44
4
or button
The time cannot be set while the C timer on is displayed.
While the A CLOCK time is displayed, press the time setting 4
/
buttons and set the time.
The setting advances one minute every time the 4
button is pressed
once, and retrogresses one minute every time the 4
button is pressed
once.
When respective 4 / buttons are pressed continuously, the time
display goes fast forward. It advances in the order of 1 minute unit - 10 minute
unit - one hour unit.
About 10 seconds after the button operation has been completed, the C cur-
rent time and A CLOCK displays disappear.
Caution:
Remote controller is equipped with a simplified clock with a precision of
about + or - one minute per month.
The time must be readjusted (reset) every time the unit is subjected to a
power stop of the unit or a power failure.
3.5. Timer setting
If the timer is set, the unit starts (stops) at the set time, and the time mode is
terminated.
When you wish to confirm the starting and ending time, press the 4 [time
selection] button while C
is displayed.
Function of timer
On-timer
Set the on-timer for the time the working day begins in your company.
When the set start time arrives, the unit starts operation.
Off-timer
Use the off-timer as a reminder to turn off the unit. When the set end-work time
arrives, the unit stops operation.
There are three methods for using the timer.
1. ON/OFF Timer When setting both starting and ending time
2. On-timer When only setting the starting time
(Ending time is set to - - : - - )
3. Off-timer When only setting the ending time
(Starting time is set to - - : - - )
Display example of timer setting
The example shows a timer set for operation start at 8:00 and end at 17:00.
1. Press the
22
22
2 [timer/continuous] button and bring up the
CC
CC
C no display
2. Press the
44
44
4 [time selection] button and bring up the
AA
AA
A Timer start time
display
3. Press the
44
44
4
( ) button of the
44
44
4 [time selection] and set the
starting time
When using it as an off-timer, set the starting time to - - : - - .
The - - : - - is displayed next to 23:50.
4. Press the
44
44
4 [time selection] button and bring up the
AA
AA
A Timer end time
display
5. Press the
44
44
4
( ) button of the [time switch] and set the ending
time
When using it as an on-timer, set the ending time to - - : - - .
The - - : - - is displayed next to 23:50.
6. Press the
22
22
2 [timer/continuous] button and bring up the
CC
CC
C
display
Bringing up the C
display completes the setting.
Every time the 4
( ) button of the 4 [timer selection] is pressed once,
it advances (or retrogresses) by 10 minutes.
If the button is pressed continuously, it advances (or retrogresses) continuously.
First set the hour digit and then set the minute digit.
When the ON/OFF timer mode is set, you can run (on-timer) or stop (off-timer)
operation by pressing the B [ON/OFF] button even when there is remaining time.
Release
Press the
22
22
2 [timer/continuous] button and disappear the display.
ON OFF
ON OFF
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Comments to this Manuals

No comments