Air-Conditioners
SEZ-KA35, KA50, KA60, KA71VA
English
∂ÏÏËÓÈο
INSTALLATION MANUAL
For safe and correct use, please read this manual and outdoor unit installation manual thoroughly before
installing the air-conditioner unit.
FOR INSTALLER
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ÛˆÛÙ‹ Î·È ·ÛÊ·Ï‹ ¯Ú‹ÛË, ‰È·‚¿ÛÙ ÚÔÛÂÎÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ, ηıÒ˜ Î·È ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ
ÂÁηٿÛÙ·Û˘ Ù˘ Â͈ÙÂÚÈ΋˜ ÌÔÓ¿‰·˜, ÚÈÓ ·fi ÙËÓ ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÙÈÎÔ‡.
POUR L’INSTALLATEUR
FÖR INSTALLATÖREN
PER L’INSTALLATORE
PARA O INSTALADOR
°π∞ ∞À∆√¡ ¶√À ∫∞¡∂π ∆∏¡ ∂°∫∞∆∞™∆∞™∏
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - Air-Conditioners

Air-ConditionersSEZ-KA35, KA50, KA60, KA71VAEnglish∂ÏÏËÓÈοINSTALLATION MANUALFor safe and correct use, please read this manual and outdoor unit insta

Page 2 - 1. Safety precautions

108.4. Filter installation points (Rear air intake) (Fig. 8-4)1. Insert the filter into rail 22. Hook the filter onto rail 3A Control boxB Drain panD

Page 3 - Fig. 3-2

11Use the canvas duct for connecting the indoor unit and the duct. (Fig. 9-1)Use fireproof material for the duct parts.Make sure that the duct has suf

Page 4 - 5. Refrigerant piping work

12• For description of each check code, refer to the following table.Check code Symptom RemarkP1 Intake sensor errorP2 Pipe (TH2) sensor errorP9 Pipe

Page 5

Please be sure to put the contact address/telephone number onthis manual before handing it to the customer.• Low Voltage Directive 73/23/ EEC• Electro

Page 6 - 6. Drainage piping work

2Contents1. Safety precautions ... 22. Selecting the installation loca

Page 7

33. Installation diagram & Accessories3.1. Indoor unit (Fig. 3-1)1 Air inlet (rear side) *Select the either back side or bottom side2 Electrical p

Page 8

44. Indoor unit installation4.1. Suspension Structure (Give site of suspensionstrong structure.)4.1.1. Wooden structure (Fig. 4-1)• Select tie beam (o

Page 9

5adcbef90°dcba5. Refrigerant piping workbaabebcdcA5.2. Flaring work• Main cause of gas leakage is defect in flaring work.Carry out correct flaring wor

Page 10 - 8. Air filter installation

67. Electrical work7.1. Precautions (Fig. 7-1)Electrical specification Input capacity Main Switch/Fuse (A)Power supply SEZ-KA35 SEZ-KA50 SEZ-KA60 SEZ-

Page 11 - 10.Test run

7Fig. 7-27.2. Indoor wire connection (Fig. 7-2)Work procedure1.Remove 2 screws to detach the electric component cover.2.Route each cable through the w

Page 12 - PAR-21MAA

87. Electrical work7.3. Remote controller7.3.1. For wired remote controller1) Installing procedures(1) Select an installing position for the remote co

Page 13 - Printed in Thailand

9Function tableSelect unit number 00ModePower failure automatic recovery*1(AUTO RESTART FUNCTION)Indoor temperature detectingLOSSNAY connectivityPower