Mitsubishi Electric FR-E700 Instruction Manual Page 1

Browse online or download Instruction Manual for Power adapters & inverters Mitsubishi Electric FR-E700. Mitsubishi Electric FR-E700 Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 59
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
FR-E700
INSTRUCTION MANUAL (BASIC)
FR-E720-0.1K to 15K
FR-E740-0.4K to 15K
FR-E720S-0.1K to 2.2K
FR-E710W-0.1K to 0.75K
INVERTER
700
5
6
7
8
9
10
4
3
2
1
CONTENTS
OUTLINE ...................................................................................1
INSTALLATION AND WIRING ...................................................6
PRECAUTIONS FOR USE OF THE INVERTER.........................18
FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER ...20
DRIVING THE MOTOR.............................................................21
ENERGY SAVING OPERATION FOR FANS AND PUMPS ........31
PARAMETERS .........................................................................32
TROUBLESHOOTING ..............................................................37
PRECAUTIONS FOR MAINTENANCE AND INSPECTION ........42
SPECIFICATIONS....................................................................44
Thank you for choosing this Mitsubishi Inverter.
This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.
Please forward this Instruction Manual (Basic) to the end user.
To obtain the Instruction Manual (Applied)
Contact where you purchased the inverter, your Mitsubishi sales
representative, or the nearest Mitsubishi FA Center for the following
manual:
y Instruction Manual (Applied) [IB(NA)-0600277ENG]
This manual is required if you are going to utilize functions and
performance.
The PDF version of this manual is also available for download at
"MELFANS Web," the Mitsubishi Electric FA network service on the
world wide web (URL: http://www.MitsubishiElectric.co.jp/melfansweb).
1
2
3
4
5
6
7
8
9
10
Page view 0
1 2 3 4 5 6 ... 58 59

Summary of Contents

Page 1 - INVERTER

FR-E700INSTRUCTION MANUAL (BASIC)FR-E720-0.1K to 15KFR-E740-0.4K to 15KFR-E720S-0.1K to 2.2KFR-E710W-0.1K to 0.75KINVERTER70056789104321CONTENTSOUTLIN

Page 2 - 4. Additional Instructions

62 INSTALLATION AND WIRINGNOTEy The life of the inverter is influenced by surrounding air temperature. The surrounding air temperature should be as lo

Page 3

72Peripheral devices2.1 Peripheral devicesCheck the inverter model of the inverter you purchased. Appropriate peripheral devices must be selected acco

Page 4 - <Related document>

8Installation of the inverter and instructions2.2 Installation of the inverter and instructions(1) Installation of the inverterEnclosure surface mount

Page 5 - 1 OUTLINE

92Wiring2.3 Wiring2.3.1 Terminal connection diagramNOTEy To prevent a malfunction caused by noise, separate the signal cables more than 10cm from the

Page 6 - 1.2 Operation panel

10Wiring2.3.2 Terminal specificationsTypeTerminal SymbolTerminal Name DescriptionMain circuitR/L1, S/L2, T/L3 *AC power inputConnect to the commercial

Page 7 - Operation panel

112Wiring2.3.3 Terminal arrangement of the main circuit terminal, power supply and the motor wiringThree-phase 200V/400V classControl circuit/output s

Page 8

12WiringSingle-phase 200V classSingle-phase 100V classFR-E720-11K, 15K FR-E740-11K, 15KFR-E720S-0.1K to 0.4K FR-E720S-0.75K to 2.2KFR-E710W-0.1K to 0.

Page 9 - Setting Description

132Wiring(1) Cable size and other specifications of the main circuit terminals and the earthing terminalSelect the recommended cable size to ensure th

Page 10 - 2 INSTALLATION AND WIRING

14WiringThe line voltage drop can be calculated by the following formula:Line voltage drop [V]=Use a larger diameter cable when the wiring distance is

Page 11 - MCCB INV

152Wiring2.3.4 Wiring of control circuitz Terminal layoutz Wiring method1) Strip off the sheath of the wire of the control circuit to wire.Strip off t

Page 12 - (2) Environment

A-1This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.Please forward this Instruction Manual (Basi

Page 13 - 2.3 Wiring

16Wiring(1) Control circuit common terminals (SD, 5, SE)Terminals SD, SE and 5 are common terminals for I/O signals. (All common terminals are isolate

Page 14 - Current input

172Connection of a dedicated external brake resistor (MRS type, MYS type, FR-ABR)2.4 Connection of a dedicated external brake resistor (MRS type, MYS

Page 15 - R/L1 S/L2 T/L3

18PRECAUTIONS FOR USE OF THE INVERTER3 PRECAUTIONS FOR USE OF THE INVERTERThe FR-E700 series is a highly reliable product, but incorrect peripheral ci

Page 16 - Single-phase 100V class

193PRECAUTIONS FOR USE OF THE INVERTER(11) Across terminals P/+ and PR, connect only an external regenerative brake discharging resistor.Do not connec

Page 17

20FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER4FAILSAFE OF THE SYSTEM WHICH USES THE INVERTERWhen a fault occurs, the inverter trips to output a fau

Page 18 - (2) Total wiring length

21Start/stop from the operation panel (PU operation)55 DRIVING THE MOTOR5.1 Start/stop from the operation panel (PU operation)5.1.1 Setting the freque

Page 19 - Wire stripping length

22Start/stop from the operation panel (PU operation)5.1.2 Setting the frequency by switches (three-speed setting) (Pr. 4 to Pr. 6)POINTy Use the opera

Page 20 - (2) Wiring instructions

23Start/stop from the operation panel (PU operation)55.1.3 Setting the frequency by analog input (voltage input)POINTy Use the operation panel ( ) to

Page 21 - MYS type, FR-ABR)

24Start and stop using terminals (External operation)5.2 Start and stop using terminals (External operation)5.2.1 Setting the frequency by the operati

Page 22

25Start and stop using terminals (External operation)55.2.2 Setting the frequency by switches (three-speed setting) (Pr. 4 to Pr. 6)POINTy Switch ON t

Page 23

A-2(2) Wiring(3) Trial run(4) Usage(5) Emergency stop(6) Maintenance, inspection and parts replacement(7) Disposalz Do not install a power factor corr

Page 24

26Start and stop using terminals (External operation)5.2.3 Setting the frequency by analog input (voltage input)POINTy Switch ON the STF(STR) signal t

Page 25 - 5 DRIVING THE MOTOR

27Start and stop using terminals (External operation)55.2.4 Operating at 60Hz or higher using the external potentiometer< How to change the maximum

Page 26 - [Connection diagram]

28Acquiring large starting torque and low speed torque (Advanced magnetic flux vector control, General-purpose magnetic flux vector control) (Pr. 71,

Page 27

29Acquiring large starting torque and low speed torque (Advanced magnetic flux vector control, General-purpose magnetic flux vector control) (Pr. 71,

Page 28

30Acquiring large starting torque and low speed torque (Advanced magnetic flux vector control, General-purpose magnetic flux vector control) (Pr. 71,

Page 29 - Deceleration

31ENERGY SAVING OPERATION FOR FANS AND PUMPS66 ENERGY SAVING OPERATION FOR FANS AND PUMPSSet the following functions to perform energy saving operatio

Page 30

32Simple mode parameters7 PARAMETERSSimple variable-speed operation can be performed with the inverter in the initial settings. Set the required param

Page 31

337Parameter list7.2 Parameter listREMARKSy indicates simple mode parameters. (initially set to extended mode)y The parameters surrounded by a black

Page 32 - , General-purpose

34Parameter list68 Retry waiting time 0.1 to 360s 1s69 Retry count display erase 0 070Special regenerative brake duty0 to 30% 0%71 Applied motor0, 1,

Page 33 - Test run

357Parameter list180 RL terminal function selection0 to 5, 7, 8, 10, 12, 14 to 16, 18, 24, 25, 62, 65 to 67, 99990181 RM terminal function selection 1

Page 34

A-3<Abbreviation>y PU: Operation panel and parameter unit (FR-PU04, FR-PU07)y Inverter: Mitsubishi inverter FR-E700 seriesy FR-E700: Mitsubishi

Page 35 - Output voltage

36Parameter list502Stop mode selection at communication error0, 1, 2, 3 0503 Maintenance timer 0 (1 to 9998) 0504Maintenance timer alarm output set ti

Page 36 - 7.1 Simple mode parameters

37Reset method of protective function88 TROUBLESHOOTINGWhen a fault occurs in the inverter, the inverter trips and the PU display automatically change

Page 37 - 7.2 Parameter list

38List of fault displays8.2 List of fault displaysWhen a fault occurs in the inverter, the inverter trips and the PU display automatically changes to

Page 38 - Parameter list

39List of fault displays8FaultOvercurrent trip during accelerationOvercurrent has occurred during acceleration.y Set the acceleration time longer. (Sh

Page 39

40List of fault displaysFaultStall prevention stopThe output frequency has dropped to 1Hz as a result of deceleration due to the excess motor load.Red

Page 40

41Check first when you have a trouble88.3 Check first when you have a trouble* For further information on troubleshooting, refer to the Instruction M

Page 41 - 8 TROUBLESHOOTING

42Inspection items9PRECAUTIONS FOR MAINTENANCE AND INSPECTIONThe inverter is a static unit mainly consisting of semiconductor devices. Daily inspectio

Page 42 - 8.2 List of fault displays

43Replacement of parts99.2 Replacement of partsThe inverter consists of many electronic parts such as semiconductor devices.The following parts may de

Page 43 - List of fault displays

44Rating10 SPECIFICATIONS10.1 Ratingz Three-phase 200V power supplyz Three-phase 400V power supplyz Single-phase 200V power supplyModel FR-E720-K 0.1

Page 44

45Common specifications10z Single-phase 100V power supply∗1 The applicable motor capacity indicated is the maximum capacity applicable for use of the

Page 45 - Description Countermeasure

11Product checking and parts identification1 OUTLINE1.1 Product checking and parts identificationUnpack the inverter and check the capacity plate on t

Page 46 - 9.1 Inspection items

46Outline dimension drawings10.3 Outline dimension drawings• Three-phase 200V class• Three-phase 400V class• Single-phase 200V class• Single-phase 100

Page 47 - 9.2 Replacement of parts

47APPENDIXThe EU Directives are issued to standardize different national regulations of the EU Member States and to facilitate freemovement of the equ

Page 48 - 10.1 Rating

48(2) Low Voltage DirectiveWe have self-confirmed our inverters as products compliant to the Low Voltage Directive (Conforming standard EN 61800-5-1)

Page 49 - 10.2 Common specifications

49∗Select a UL and cUL certified fuse with Class T fuse equivalent cut-off speed or faster with the appropriate rating forbranch circuit protection, o

Page 50 - Outline dimension drawings

50(Standard to comply with: UL 508C, CSA C22.2 No. 14)1. General PrecautionThe bus capacitor discharge time is 10 minutes. Before starting wiring or i

Page 53 - Operation time (s)

53REVISIONS*The manual number is given on the bottom left of the back cover. For Maximum Safety• Mitsubishi inverters are not designed or manufactured

Page 54 - 5. Motor overload protection

54International FA CenterKorean FA CenterBeijing FA CenterEuropean FA CenterUK FA CenterCentral and Eastern Europe FA CenterTianjin FA CenterShanghai

Page 55

HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANMODELMODELCODE1A2-P25FR-E700INSTRUCTION MANUAL (BASIC)IB(NA)-0600441EN

Page 56

2Operation panel1.2 Operation panel1.2.1 Names and functions of the operation panelThe operation panel cannot be removed from the inverter.Operation m

Page 57 - Revision

31Operation panel1.2.2 Basic operation (factory setting)STOPOperation mode switchoverParameter settingFaults history Monitor/frequency settingAt power

Page 58 - International FA Center

4Operation panel1.2.3 Changing the parameter setting valueChanging exampleChange the Pr. 1 Maximum frequency setting.Operation Display 1.Screen at pow

Page 59

51Operation panel1.2.4 Parameter clear/all parameter clearPOINTy Set "1" in Pr.CL Parameter clear, ALLC all parameter clear to initialize a

Comments to this Manuals