The secret to the unmatched comfort provided by Lossnay core is the cross-flow, plate-fin structure off the
heat-exchange unit. A diaphragm made of a specially processed paper fully separates inducted and exhausted air
supplies, ensuring that only fresh air is introduced to the indoor environment.
The superior heat-transfer and moisture permeability of the special paper assure highly effective total heat exchange
(temperature and humidity) when inducted and exhausted air supplies cross in the Lossnay core.
Combine with Lossnay Ventilation System Enhanced Air Quality.
Unified Control System Allows Greater Design Freedom.
Stale hot air (exhaust)
Fresh cool air (outdoor)
0°C (32°F)
4°C (39.2°F)
20°C (68°F)
16°C (60.8°F)
Fresh warm air (indoor supply air)
Stale warm air (indoor air)
Heat-Exchange Efficiency Obtainable Only with Lossnay.
LGH-15RX5 [150m
3
/h Single phase 220-240V 50Hz]
LGH-25RX
5 [250m
3
/h Single phase 220-240V 50Hz]
LGH-35RX
5 [350m
3
/h Single phase 220-240V 50Hz]
LGH-50RX
5
[500m
3
/h Single phase 220-240V 50Hz]
LGH-65RX
5 [650m
3
/h Single phase 220-240V 50Hz]
LGH-80RX
5 [800m
3
/h Single phase 220-240V 50Hz]
LGH-100RX
5 [1000m
3
/h Single phase 220-240V 50Hz]
LGH-150RX
5 [1500m
3
/h Single phase 220-240V 50Hz]
LGH-200RX
5
[2000m
3
/h Single phase 220-240V 50Hz]
The Ventilation System for Enhanced Air Quality - Lossnay
RX5 SERIES
• Two paths ventilation
LOSSNAY simultaneously intakes Fresh Air and exhausts Dirty Air.
• Total energy recover
LOSSNAY returns BOTH sensible heat and latent heat.
LOSSNAY Technology
• Hyper Eco Core
Spacer plate
Partition plate
Fresh air induction
(fresh air)
Fresh air exhaust
(fresh heating/cooling air)
Stale air exhaust
(dirty indoor air)
Stale air induction
(dirty heating/cooling air)
Sensible heat Latent heat
IndoorsOutdoors
EA SA
RAOA
A. Two paths ventilation B. Total Energy transfer
64%
65%
66%
67%
68%
69%
70%
71%
72%
73%
74%
15RX 25RX 35RX 50RX 65RX 80RX 100RX 150RX 200RX
RX5
*Cooling, High Fan speed, 50Hz
Enthalpy exchange efficiency improve
Spacerplates
Dividerplates
Humidity
Improved adhesive
agent material
RX4
Mitsubishi's newly developed Hyper Eco Element is on
board, offering the industry's best total heat exchange
efficiency. Energy conservation performance has been
improved not only by reducing the air conditioning load
associated with ventilation, but also by facilitating humidity
penetration.
Introducing the new Hyper Eco Element
Better energy conservation by improved total heat exchange efficiency.
Hyper Element
Humidity does not
penetrate easily.
Adhesive agent
with low humidity
penetration rate
Humidity penetration is
facilitated.
New adhesive agent
with high humidity
penetration rate
Hyper Eco Element
Outdoors Indoors
EA
(exhaust air)
OA
(outside air)
RA
(return air)
OA
(outside air)
SA
(supply air)
RA
(return air)
Element Structure