8-10. INDIRECT/DIRECT mode
The INDIRECT/DIRECT mode offers nely-tuned operation by locating where an occupant is in the room.
(1) Press INDIRECT/DIRECT button during COOL, DRY, HEAT or AUTO mode to activate INDIRECT/DIRECT mode.
This mode is only available when the i-see control mode is effective.
(2) Each press of INDIRECT/DIRECT button changes INDIRECT/DIRECT in the following order:
(INDIRECT): An occupant will be less exposed to direct airow.
(DIRECT) : Mainly the vicinity of an occupant will be air-conditioned.
(INDIRECT) (DIRECT) (OFF)
NOTE:
• Horizontal and vertical air ow directions will be automatically selected.
• If you still feel uncomfortable with the air direction determined by the INDIRECT mode, adjust the air direction manually.
• Cancelling the i-see control mode automatically cancels the INDIRECT/DIRECT mode.
INDIRECT/DIRECT mode is also cancelled when the VANE or WIDE VANE buttons is pressed.
• Do not touch the i-see SENSOR. This may cause malfunction of the i-see SENSOR.
8-9. i-see CONTROL ( ) MODE
In the i-see control mode, the room temperature is controlled based on the sensible temperature.
(1)
Press SENSOR button with a thin instrument during COOL, DRY, HEAT and AUTO mode to activate i-see control mode ( ).
The default setting is “active”.
(2) Press SENSOR button again to activate ABSENCE DETECTION ( ).
(3) Press SENSOR button again to release i-see control mode.
ABSENCE DETECTION ( )
This function automatically changes the operation to energy-saving operation when nobody is in the room.
(1) To activate this function, press SENSOR button until appears on the operation display of the remote controller during the
i-see control mode.
(2) Press SENSOR button again to release ABSENCE DETECTION.
2. Checking weekly timer setting
2. Checking weekly timer setting
(1) Press button to enter the weekly timer setting mode.
*
blinks.
(2) Press
or buttons to view the setting of the particular day or number.
(3) Press
button to exit the weekly timer setting.
NOTE:
When all days of the week are selected to view the settings and a different setting is included among them,
will be
displayed.
(5) Press
button to turn the weekly timer ON. ( lights.)
•When the weekly timer is ON, the day of the week whose timer setting is complete, will light.
Press
button again to turn the weekly timer OFF. ( goes out.)
NOTE:
The saved settings will not be cleared when the weekly timer is turned OFF.
NOTE:
Any person at the following places cannot be detected:
Along the wall on which the air conditioner is installed
• Directly under the air conditioner
• Where any obstacle, such as furniture, is between the person and the air conditioner
A person may not be detected in the following situations:
• Room temperature is high.
A person wears heavy clothes and his/her skin is not exposed.
A heating element of which temperature changes signi cantly is present.
• Some heat sources, such as a small child or pet, may not be sensed.
A heat source and the air conditioner are more than 20 ft. (6 m) apart.
A heat source does not move for a long time.