Mitsubishi Electric PUHZ-HA2 Installation Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
8
A
B
C
D
E
6. Electrical work
Fig. 6-1
Fig. 6-2
RP60-140
RP35, 50V
A Earth terminal
B Terminal block
C Clamp
D Service panel
E Wire the cables so that they do not
contact the center of the service
panel or the gas valve.
6.1. Outdoor unit (Fig. 6-1, Fig. 6-2)
1 Remove the service panel.
2 Wire the cables referring to the Fig. 6-1 and the Fig. 6-2.
A
C
D
B
S3
S3
S2
S1
N
L
S2S1LN
D
D
E
EEE
C
B
A
D D D
A A
A Indoor unit
B Outdoor unit
C Remote controller
D Main switch (Breaker)
E Earth
Outdoor unit model
Outdoor unit power supply
Outdoor unit input capacity *1
Main switch (Breaker)
Outdoor unit power supply
Outdoor unit power supply earth
Indoor unit-Outdoor unit *2
Indoor unit-Outdoor unit earth *2
Remote controller-Indoor unit *3
Outdoor unit L-N (single)
*4
Outdoor unit L1-N, L2-N, L3-N (3 phase)
Indoor unit-Outdoor unit S1-S2 *4
Indoor unit-Outdoor unit S2-S3 *4
Remote controller-Indoor unit *4
Wiring
Wire No. ×
size (mm
2
)
Circuit rating
RP35, 50V RP60, 71V RP100, 125V RP140V RP100, 125, 140Y
~/N (single), 50 Hz, ~/N (single), 50 Hz, ~/N (single), 50 Hz, ~/N (single), 50 Hz, 3N ~ (3phase), 50 Hz,
230 V 230 V 230 V 230 V 400 V
16 A 25 A 32 A 40 A 16 A
2 × Min. 1.5 2 × Min. 2.5 2 × Min. 4 2 × Min. 6 4 × Min. 1.5
1 × Min. 1.5 1 × Min. 2.5 1 × Min. 4 1 × Min. 6 1 × Min. 1.5
3 × 1.5 (Polar) 3 × 1.5 (Polar) 3 × 1.5 (Polar) 3 × 1.5 (Polar) 3 × 1.5 (Polar)
1 × Min. 1.5 1 × Min. 1.5 1 × Min. 1.5 1 × Min. 1.5 1 × Min. 1.5
2 × 0.3 (Non-polar) 2 × 0.3 (Non-polar) 2 × 0.3 (Non-polar) 2 × 0.3 (Non-polar) 2 × 0.3 (Non-polar)
AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V
AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V
DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V
DC 12 V DC 12 V DC 12 V DC 12 V DC 12 V
*1. A breaker with at least 3.0 mm contact separation in each poles shall be provided. Use non-fuse breaker (NF) or earth leakage breaker (NV).
*2. Max. 45 m
If 2.5 mm
2
used, Max. 50 m
If 2.5 mm
2
used and S3 separated, Max. 80 m
For RP100, 125, 140Y application, use shield wires. The shield part must be grounded with the indoor unit OR the outdoor unit, NOT with both.
*3. The 10 m wire is attached in the remote controller accessory.
*4. The figures are NOT always against the ground.
S3 terminal has DC 24 V against S2 terminal. However between S3 and S1, these terminals are NOT electrically insulataed by the transformer or other device.
Notes: 1. Wiring size must comply with the applicable local and national code.
2. Power supply cords and Indoor/Outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 245 IEC 57)
3. Install an earth longer than other cables.
6.2. Field electrical wiring
For Heater
*With Heater
model only
For Power
For Power
For Heater For Heater For Heater
LN
S1 S2 S3
L1 L2 L3 N
S1 S2 S3
E
B
A
F
C
RP100-140Y
RP60-140V
S1
S2
S3
S1
S2
S3
Warning:
In case of A-control wiring, there is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power line
and communication signal line. Therefore, please turn off the main power supply when servicing. And do not touch the S1, S2, S3 terminals when the power is
energized. If isolator should be used between indoor unit and outdoor unit, please use 3-poles type.
LN
S1 S2 S3
230V
Single phase
Isolator
3 poles isolator
A-Control
Outdoor Unit
A-Control
Indoor Unit
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments