Mitsubishi-electric MR-J2S- A User Manual Page 116

  • Download
  • Add to my manuals
  • Print
  • Page
    / 402
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 115
3 - 69
3. SIGNALS AND WIRING
Signal Name Abbreviation Description
Power supply U V W Connect to the motor output terminals (U, V, W) of the servo amplifier.
Supply power which satisfies the following specifications.
Servo motor
Voltage
division
Voltage/frequency
Power
consumption
[W]
Rated
current
[A]
HA-LFS601, 701M,
11K2
200V
class
1-phase 200 to 220VAC
50Hz
1-phase 200 to 230VAC
60Hz
42(50Hz)
54(60Hz)
0.21(50Hz)
0.25(60Hz)
HA-LFS801 12K1,
11K1M, 15K1M,
15K2, 22K2
3-phase 200 to 230VAC
60Hz
62(50Hz)
76(60Hz)
0.18(50Hz)
0.17(60Hz)
HA-LFS-15K1,
20K1, 22K1M
65(50Hz)
85(60Hz)
0.20(50Hz)
0.22(60Hz)
HA-LFS25K1 120(50Hz)
175(60Hz)
0.65(50Hz)
0.80(60Hz)
Cooling fan
(Note)
BU
BV BW
Motor thermal relay OHS1 OHS2 OHS1-OHS2 are opened when heat is generated to an abnormal temperature.
Earth terminal
For grounding, connect to the earth of the control box via the earth terminal of the servo
amplifier.
Note. Cooling fan power supply of the HA-LFS11K2 servo motor is 1-phase. Power supply specification of the cooling fan is different
from that of the servo amplifier. Therefore, separate power supply is required.