Mitsubishi Electric MS-GF60VA Service Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
26
10-5. TROUBLE CRITERION OF MAIN PARTS
Part name Check method and criterion Figure
Room temperature
thermistor (RT11)
Indoor coil thermistor
(RT12)
Measure the resistance with a tester.
Refer to 10-7. "Test point diagram and voltage", "1. Indoor electronic control
P.C. board", for the chart of thermistor.
MS-GF20/25/35VA
Indoor fan motor (MF)
INNER FUSE
145 °C CUT OFF
Measure the resistance with a tester.
(Part temperature 10 ~ 30 °C)
Color of the lead wire Normal
WHT-BLK 334 Ω ~ 362 Ω
BLK-RED 370 Ω ~ 402 Ω
MS-GF50/60/80VA
Indoor fan motor (MF)
Check 10-6. "Check of indoor fan motor".
MS-GF20/25/35VA
Horizontal vane motor
(MV)
Measure the resistance between the terminals with a tester.
(Temperature: 10 - 30°C)
Color of the lead wire Normal
RED-BLK 223 Ω ~ 268 Ω
BLK
BLK
RED
BLK
BLK
ROTOR
MS-GF50/60/80VA
Horizontal vane motor
(MV1)
Vertical vane motor
(MV2)
Measure the resistance between the terminals with a tester.
(Temperature: 10 - 30°C)
Color of the lead wire Normal
Horizontal vane motor (MV1)
RED-BLK
313 ~ 375 Ω
Vertical vane motor (MV2) 268 ~ 322 Ω
MAIN
AUX.
BLK
RED WHT
FUSE
OBH621A
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 41 42

Comments to this Manuals

BryanThubs 07 Apr 2024 | 20:32:56

Hello! Crazy discounts, hurry up! We are Drop Dead Studio and our goal is to help companies achieve impressive sales results through automated marketing. I. [b]We sell fresh databases for GSA Search Engine Ranker.[/b] • The databases are updated monthly through 24/7 parsing and by connecting purchased databases from other sources. • You have the option to purchase a one-time fresh database or pay for a lifetime subscription for updates. [i][b]ATTENTION![/b][/i] 40% discount only until