3. Indoor electronic control P.C. board, Indoor terminal P.C. board, Power monitor receiver SW P.C. board
MS-GF50VA MS-GF60VA MS-GF80VA
Power monitor receiver SW P.C. board
Emergency
operation switch
(E.O. SW)
(SW1)
CN20A
(–)
(+)
(Refer to 10-6. .)
Indoor electronic control P.C. board
Indoor terminal P.C. board
Indoor fan motor
(CN211)
325 VDC
(–) GND
(high-voltage DC)
15 VDC
(+)3-6 VDC
(+)0 or 15 VDC
Resistor
(R111)
Timer short mode point
JPG JPS (Refer to 8-1.)
Varistor
(NR11)
Terminal
block
To disable "Auto restart function",
cut the Jumper wire to JR77.
(Refer to 8-3.)
Vane motor
(CN151,
CN152)
5VDC
12 VDC
Room temperature
thermistor RT11
(CN111)
Indoor coil thermistor
RT12 (main) (CN112)
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12)
Tem
p
erature
(
°C
)
Resistance (kΩ)
Fuse
(F11)( )
Replace the fuse after removing the indoor terminal P.C. board from the electrical box.
GND
OBH621A
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 40 41 42

Comments to this Manuals

BryanThubs 07 Apr 2024 | 20:32:56

Hello! Crazy discounts, hurry up! We are Drop Dead Studio and our goal is to help companies achieve impressive sales results through automated marketing. I. [b]We sell fresh databases for GSA Search Engine Ranker.[/b] • The databases are updated monthly through 24/7 parsing and by connecting purchased databases from other sources. • You have the option to purchase a one-time fresh database or pay for a lifetime subscription for updates. [i][b]ATTENTION![/b][/i] 40% discount only until