10-2. MSZ-FE18NA
NOTE: Turn OFF power supply before disassembly.
OPERATING PROCEDURE PHOTOS
1. Removing the panel
(1) Remove the horizontal vanes.
(2) Remove the screw caps of the panel. Remove the
screws of the panel.
(3) Hold the lower part of both ends of the panel and pull
it
slightly toward you, and then remove the panel by
pushing
it upward.
Photo 1
Photo 2
2. Removing the indoor electronic control P.C.
board, the power monitor receiver SW P.C. board
and the indoor terminal P.C. board
(1) Remove the panel (Refer to 1.) and the corner box.
(2) Remove the screw of the V.A. clamp and the V.A.
clamp.
(3) Remove the screw of the conduit cover and the con-
duit cover. (Photo 3)
(4) Remove the screw of the conduit plate, the conduit
plate and the indoor/outdoor connecting wire.
(5) Remove the screw of the electrical cover, and then
the electrical cover.
(6) Remove the ground wire connected to the indoor
electronic control P.C. board from the electrical box.
(Photo 3)
(7) Remove the power monitor receiver holder.
(8) Open the rear cover of the power monitor receiver
holder and pull out the power monitor receiver SW P.C.
board.
(9) Disconnect all the connectors on the indoor electronic
control P.C. board and unhook all lead wires.
(10)
Remove the screw of the terminal block on the indoor
terminal P.C. board.
(11)
Remove the indoor terminal P.C. board and the indoor
electronic control P.C. board.
Screws of the panel
Front panel
Horizontal vanes
Power monitor
receiver holder
Screw of the
electrical cover
Electrical box
Screw of the
V.A. clamp
Page view 39