Mitsubishi Electric MUX-25TV - E1 User Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
R4
6.8K.
2VV
117V
ac
-1
SO2
M0V2
ON.0
F1
NC
y
0--À
I
K1
D6
1N4001
1C
D7
1N4001
D1
D4 =
I
1N5400=
I
M 0 V
1
sol
01
R1
J1si
100
______
C2
100
NF
D8
12V'1
1W
D5
Cl
1N4001
100NF
R2
4.7K
2111
113
4.7K
2W
S7-S16
1
0-
.,
.
4 oti
0-0
-
6.
0--
ó .
12
0-
o
160-e
o
O NC
O 41
20
o-*
o
o
..-
24
0
o
o
o
28
0
0
320
o ++
O NC
0
NC
360NC
16
In p
Toggle 1
\
Out
o
.,
""'S1:2
15
o
r
13
3
o
Q 24
o
o
O
0 28
O
o
0
32
NC 0
NC
0
16
NC036
dódbbdbbbdddoobeb0d'dbóedddó
8ddddo
0oo
1 4
8
12 18
20
24
28
32
36
Compter
á
aFig. I. This
is the schematic
diagram
of the Smart Power
Switch. Turning
on /off
the device
plugged into SOI
automatically turns
on
/off
any de-
vice
plugged into
502.
of
relay KI to ground
applying
12
volts
to the
relay's coil and
closing
its
lower contacts.
With K's
contacts
closed,
ac
line
power
is applied to slave
receptacle
502.
Resistors
R2, R3 and
R4 form
one side
of the ac
line
and
in series
with rectifier diode D7 and
zener di-
ode
D8
supply
the
12
volts
dc for
K1.
(Note: These three
resistors can
be
replaced with a single
2000 -ohm,
6 -watt or
more resistor.)
Fuse FI
protects
the
circuit and
should be selected to
accommodate
the total load
expected to be drawn
by the devices plugged
into
the
mas-
ter and slave
receptacles.
Of
course,
you
must make
sure that this load
does not exceed the amount
of
power
that
can be safely
handled
by
KI's
contacts. If you wish, you
can substi-
tute
an appropriately
rated
circuit
breaker for the fuse. Finally, MO
VI
and
MO V2
are included in the
circuit
to provide spike protection for
any
devices
plugged
into
SOI and 502.
You
can assemble the Smart
Switch on
a printed- circuit board of
your own
design or a piece of
perfor-
ated board and use solder
posts
to
make the interconnections,
using
point -to -point wiring. If you install
the project in
a
metal
case, be sure to
insulate it well
to protect users from
electrical shock . Also, be sure to use
a
3- conductor
grounded
ac
line
cord
and receptacles and to properly
phase the
cord and
receptacles.
Two
-Way Printer
Switch
Here
you
have a choice of a parallel
or
a
serial
switch. The parallel
ver-
pFig. 2. Use this
wiring
diagram
to as-
semble the printer switch
for
Cen-
tronics- compatible parallel
printers.
Say
You Saw It In Modern Electronics
April 1986
/
MODERN ELECTRONICS /
51
Page view 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 83 84

Comments to this Manuals

No comments