Notes:
PWFY-P100VM-E-BU
Power input
Current input
Outdoor unit/Heat
source unit condition
Booster unit inlet water temp.
Total capacity
Model / Quantity
Liquid
Gas
Inlet
Outlet
Type
Maker
Starting method
Motor output
Lubricant
Operation volume Range
High pressure protection
Inverter circuit (COMP)
Compressor
Type × original charge
Control
R410A
R134a
Water
External
Wiring
Document
Accessory
<WR2-series>
Circulating water Temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 65°C Water flow rate 2.15m
3
/h
* Due to continuing improvement, the above specifications may be subject to change without notice.
* The unit is not designed for outside installations.
* Please don't use the steel material for the water piping material.
* Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 0°C (32°F) or less.
* Please always make water circulate or pull out the circulation water completely when not using it.
* Please do not use groundwater and well water.
* Install the unit in an environment where the wet bulb Temp. will not exceed 32°C (90°F).
* The water circuit must use the closed circuit.
* Please do not use it as a drinking water.
1-phase 220-230-240V 50 / 60Hz
12.5
10,800
42,700
2.48
11.63-11.12-10.66
-20~32°C (-4~90°F) R2-series
10~45°C (50~113°F) WR2-series
10~70°C (50~158°F)
50~100% of outdoor unit/heat source unit capacity
R2 (Standard, Hi-COP), Replace R2, WR2 series only
44
ø9.52 (ø3/8") Brazed
ø15.88 (ø5/8") Brazed
PT3/4 Screw
PT3/4 Screw
ø32 (1-1/4")
NO
800 (785 without legs) × 450 × 300
31-1/2" (30-15/16" without legs) × 17-3/4" × 11-13/16"
60 (133)
Inverter rotary hermetic compressor
MITSUBISHI ELECTRIC CORPORATION
Inverter
1.0
NEO22
0.6~2.15
High pressure sensor, High pressure switch at 3.60 MPa (601 psi)
Over - heat protection, Over - current protection
Discharge thermo protection, Over - current protection
R134a × 1.1kg (0.50lb)
LEV
4.15
3.60
1.00
WKB94L762
WKE94C229
Installation Manual, Instruction Book
Strainer, Heat insulation material, 2 × Connector sets
NONE
*1
*1
*1
*2
Power source
Connectable outdoor
unit/
heat source unit
Sound pressure level (measured in anechoic room)
Diameter of refrigerant
pipe
Diameter of water
pipe
Field drain pipe size
External finish
Net weight
Compressor
Circulating water
Design pressure
Optional parts
Model
Heating capacity
(Nominal)
Temp. range of
heating
External dimension H × W × D
Protection on internal
circuit (R134a)
Refrigerant
Drawing
Standard attachment
Remark
kW
kcal/h
BTU/h
kW
A
W.B.
-
-
dB<A>
mm(in.)
mm(in.)
mm(in.)
mm(in.)
mm(in.)
mm
in.
kg(lbs)
kW
m
3
/h
MPa
MPa
MPa
*1 Nominal heating conditions
<R2-series>
Outdoor Temp. : 7°CDB/6°CWB (45°FDB / 43°FWB)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 65°C Water flow rate 2.15m
3
/h
*2 Do not use refrigerant other than the type indicated in the manuals provided with the unit and on the nameplate.
- Doing so may cause the unit or pipes to burst, or result in explosion or fire during use, during repair, or at the
time of disposal of the unit.
- It may also be in violation of applicable laws.
- MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting
from the use of the wrong type of refrigerant.
Details on foundation work, duct work, insulation work, electrical wiring, power source
switch, and other items shall be referred to the Installation Manual.
ATW UNIT
Booster Unit
PWFY-P VM-E-BU
Specications
116