Mitsubishi Electric City Multi PFFY-P63VLRMM-E Specifications Page 126

  • Download
  • Add to my manuals
  • Print
  • Page
    / 168
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 125
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
LGH-50RX
5-E
LGH-50RX5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
1.2-1.25
255-286
500
139
15.3-15.8
150-155
78.0
69.0
66.5
33-34
1.0-1.0
207-228
500
139
6.6-9.2
65-90
78.0
69.0
66.5
30.5-32
0.85-0.85
175-190
390
108
4.1-6.1
40-60
81.0
71.0
68.0
26.5-28
0.4-0.4
80-95
180
50
1.0
10
86.0
78.0
77.0
19
Extra High High Low Extra Low
1.25-1.25
260-290
500
139
15.3-15.8
150-155
34-35
1.0-1.0
210-230
500
139
6.6-9.2
65-90
31-32.5
0.85-0.85
180-195
390
108
4.1-6.1
40-60
27-29
0.4-0.4
80-95
180
50
1.0
10
19
32
Under 3.0 A Less
*The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 16 dB greater than the indicated value. (at High Fan speed)
Frequency / Power source
50Hz / Single phase 220-240V
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
LGH-65RX
5-E
LGH-65RX5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
1.7-1.8
350-380
650
181
11.2-12.2
110-120
77.0
68.5
66.0
34-34.5
1.5-1.5
308-322
650
181
6.1-8.2
60-80
77.0
68.5
66.0
32-33
1.2-1.2
248-265
520
144
4.1-5.1
40-50
80.0
70.5
68.5
28.5-31.5
0.6-0.6
120-140
265
74
0.8
8
86.0
78.0
77.0
22
Extra High High Low Extra Low
1.7-1.8
350-385
650
181
11.2-12.2
110-120
34.5-35
1.5-1.5
310-335
650
181
6.1-8.2
60-80
32.5-33.5
1.2-1.2
250-265
520
144
4.1-5.1
40-50
28.5-30.5
0.6-0.6
120-140
265
74
0.8
8
22-22.5
40
Under 4.4 A Less
*The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 10 dB greater than the indicated value. (at High Fan speed)
Frequency / Power source
50Hz / Single phase 220-240V
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
LGH-80RX
5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
1.75-1.75
380-415
800
222
14.8-15.3
145-150
79.0
71.0
70.0
33.5-34.5
1.6-1.6
345-370
800
222
10.7-12.2
105-120
79.0
71.0
70.0
32-33
1.45-1.45
315-340
700
194
8.2-9.7
80-95
80.5
72.5
71.5
30-31
0.60-0.65
125-145
355
99
2
20
87.5
79.5
79.5
22
Extra High High Low Extra Low
1.75-1.75
380-415
800
222
14.8-15.3
145-150
34.5-35.5
1.6-1.6
345-370
800
222
10.7-12.2
105-120
33-34
1.45-1.45
315-340
700
194
8.2-9.7
80-95
31-32
0.60-0.65
120-145
355
99
2
20
22
53
Under 3.8 A Less
*The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 16 dB greater than the indicated value. (at High Fan speed)
Frequency / Power source
50Hz / Single phase 220-240V
LGH-80RX5-E
LGH-15~100RX5-E
126
Indoor Unit
Page view 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 167 168

Comments to this Manuals