Mitsubishi Electric KA60VA Service Manual

Browse online or download Service Manual for Split-system air conditioners Mitsubishi Electric KA60VA. Mitsubishi Electric KA60VA Service manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Home > Products > M Series > R410A Ceiling Concealed Ducted System > Inverter Heat Pump >
R410A Ceiling Concealed Ducted System
SEZ-KA60VA Indoor Unit
Capacity (kW):
Heating (Nominal) (Low
- High)
6.90 (0.90 - 8.00)
Cooling (Nominal) (Low
- High)
5.50 (1.10 - 6.30)
Heating (UK) (Low -
High)
5.75 (0.75 - 6.65)
Cooling (UK) (Low -
High)
5.45 (1.10 - 6.25)
SHF R410A (Nominal) 0.75
COP / EER (Nominal) 2.82 / 2.81
Energy Label Heating /
Cooling
C / D
Width - mm 1100
Depth - mm 700
Height - mm 270
Weight - kg 33.5
Airflow (m3/min)
(Heating / Cooling) -
Lo-Hi
12-20 / 12-20
SEZ-KA60VAInverter Heat Pump
Designed for homes, offices, restaurants or shops, the SEZ series operates at
low noise levels and is virtually invisible when installed within a suspended
ceiling. Its low unit height and lightweight design also helps to make
installation easier and more convenient.
Hover your mouse over the red icons below to view a description of each feature:
Model Info
[Print]
[
Print]
Dimensions
SEZ-KA60VA (Click to
enlarge).
SUZ-KA60VA (Click to
enlarge).
Page view 0
1 2 3 4 5 6 ... 21 22

Summary of Contents

Page 1 - SEZ-KA60VAInverter Heat Pump

Home > Products > M Series > R410A Ceiling Concealed Ducted System > Inverter Heat Pump > R410A Ceiling Concealed Ducted System SEZ-KA6

Page 2

8OUTLINES AND DIMENSIONS3SEZ-KA35VA.THSEZ-KA50VA.THSEZ-KA60VA.THUnit : mm(10) 50508807x100=700100409 x 2-{2.9 holes1000503860680350Suspension bolt pit

Page 3

94WIRING DIAGRAMSEZ-KA35VA.THSEZ-KA50VA.THSEZ-KA60VA.THSWEOFFONSW3OFF54321ONSW2OFF54321ON(POWER BOARD)CNDK REDREDWHTZNRFUSEREDBLUCND(POWER) ORNBLUYLW

Page 4 - PART NAMES AND FUNCTIONS

10REFRIGERANT SYSTEM DIAGRAM5Pipe temperature thermistor/liquid (TH2)Distributorwith strainer#50Condenser/evaporator temperature thermistor(TH5)Room t

Page 5 - FUNCTION

116TROUBLESHOOTING6-1. Cautions on troubleshooting(1) Before troubleshooting, check the followings: 1 Check the power supply voltage.2 Check the indoo

Page 6 - SPECIFICATIONS

126-3. Test point diagram6-3-1. Indoor power boardSEZ-KA35VA.THSEZ-KA50VA.THSEZ-KA60VA.THCNSKConnect to the indoor controller board(CNDK)Between 11 t

Page 7

136-3-2. Indoor controller boardSEZ-KA35VA.THSEZ-KA50VA.THSEZ-KA60VA.THFANFan motor outputCNDKConnect to the indoorpower board (CNSK)(220~240V AC)FUSE

Page 8

146-4. Trouble criterion of main partsSEZ-KA35VA.THSEZ-KA50VA.THSEZ-KA60VA.THBLK REDGRNYLWORNYLWBLUBRNWHTPRoom temperaturethermistor(TH1)Condenser/eva

Page 9

15DISASSEMBLY PROCEDURE71. Removing the electrical parts(1) Remove the 2 screws and the electrical parts cover.(See Photo 1.)● Indoor controller board

Page 10 - OUTLINES AND DIMENSIONS

164. Removing the room temperature thermistor (TH1)(1) Remove the electrical parts cover. (Refer to 1.)(2) Remove the 12 screws and the front panel at

Page 11 - WIRING DIAGRAM

176. Removing the drain pan(1) Unscrew each set screw on the right and left, and remove the drain pan pushing it toward the the back.(See Photo 1.)P

Page 12 - REFRIGERANT SYSTEM DIAGRAM

External Static Pressure Pa(mmAq) - Lo-Hi30(3)-50(5)Noise (dBA) (Heating /Cooling) - Lo-Hi32-43 / 32-43Pipe Size Gas mm (in) 15.88 (5/8)Pipe Size Liqu

Page 13 - TROUBLESHOOTING

18PARTS LIST8No.Parts No.Parts nameSpecificationRemarksUnitAmountWiringDiagramSymbolRecom-mendedQ'tyQ'ty/setPrice123456789101112131415LEFT S

Page 14 - SEZ-KA60VA.TH

1912S3S2S1TO REMOTECONTROLLERTO OUTDOORUNITNo.Parts No.Parts nameSpecification250V/6.3A2.5+3.0+2P3PRemarks(Drawing No.)UnitAmountWiringDiagramSymbolRe

Page 15

9OPTIONAL PARTS9-1. REFRIGERANT PIPESThe air conditioner has flared connections its indoor and outdoor sides.Please use the optional extension pipe as

Page 16

TECHNICAL & SERVICE MANUALCONTENTS1. PART NAMES AND FUNCTIONS········22. SPECIFICATIONS·································43. OUTLINES AND DIMENSION

Page 17 - DISASSEMBLY PROCEDURE7

21PART NAMES AND FUNCTIONSIndoor UnitSEZ-KA35VA.TH SEZ-KA50VA.TH SEZ-KA60VA.TH Air outlet duct flangeAir outletAir inlet(Selecting the either back s

Page 18 - Photo 6

3● DisplayFor purposes of this explanation,all parts of the display are shownas lit. During actual operation, onlythe relevant items will be lit.˚F˚C˚

Page 19 - Photo 9

42SPECIFICATIONSSEZ-KA35VA.TH SEZ-KA50VA.THIndoor modelFunctionPower supplySingle phase230V, 50Hz780/600100.4060—0.22 PK6V19-EF1100o270o70033.5135/30

Page 20 - PARTS LIST8

5SEZ-KA60VA.THIndoor modelFunctionPower supplySingle phase230V, 50Hz1200/720200.65100—0.39 PK6V50-EF1100o270o70033.5143/32 890/6603Std : 30 Max :

Page 21 - ELECTRICAL PARTS

690807060504030201063 125 250 500 1000 2000 4000 8000APPROXIMATETERESHOLD OFHEARING FORCONTINUOUSNOISENC-60NC-50NC-40NC-30NC-20NC-70OCTAVE BAND SOUND

Page 22 - OPTIONAL PARTS

7Air flow (K/X)Recommended range 80 60 40200105 7 15 20 25External static pressure(Pa)(1Pa = 0.1mmAq)Fan PerformanceAir flow (K/X)Recommended range