<RECORD SETTINGS> (continued)
When select and set the TRIGGER setting to
MD, MD/EXT or MD&EXT, the motion detection func-
tion will be active soon and any setting alteration
can not be accepted. Please use effectively the
ALARM INTERRUPT button to change the setting.
9. When the setting is complete, turn the SHUTTLE ring
counterclockwise.
The cursor moves to the camera number on the left.
When continuing with other camera number settings, turn
the JOG dial to move the cursor to the desired camera number
and repeat steps 4 ~ 9 to perform the settings.
10. (When setting recording intervals and recording picture
quality )
Press the SET UP button
}
<SETTINGS>
}
Select RECORD
SETTING in the <RECORD SETTINGS> screen and turn the
SHUTTLE ring clockwise.
The <RECORD SETTING> screen appears.
<RECORD SETTING> ALARM CH
NO PPS GRADE A-PPS A-GRADE
>>
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
NEXT PAGE SHUTTLE<<:BACK
<RECORD SETTING> 1/2
Camera selection during alarm recording
9
7
4
5
6
1
2
3
8
<RECORD SETTING> 2/2
10
11
13
14
15
16
12
CAUTION : For <ESTD REC>, see
Continuous recording time table, pages 88, 89.
Appears when PARTITION
(LONG PRE-ALARM) is set.
<RECORD SETTING> ALARM CH
NO PPS GRADE A-PPS A-GRADE
>>
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
1.563P STD 1.563P STD
PRE ALARM REC ( S ) S
SHUTTLE<<:BACK
<ESTD REC> D H M %
The storage area in MAIN HDD set in PARTI-
TION is displayed with the percentage(%) and the
recordable time of that storage area is displayed in
<ESTD REC>.
The <RECORD SETTING> screen consists of 2
pages. The second page is displayed when turning
the JOG dial to move the cursor to NEXT PAGE,
and turn the SHUTTLE ring clockwise.
11. (When setting the recording intervals and recording picture
quality for normal recording
)
Turn the JOG dial to select the desired camera number and
turn the SHUTTLE ring clockwise twice.
The background of the PPS display changes to red and flashes.
Setting of PPS ( default : 1.563P )
3.125P, 1.563P, 1.042P, 0.781P, 0.625P, 0.521P,
0.391P, 0.313P, 0.125P, 0.063P, 0.031P, 0.016P,
- - - - - -
- - - - - - : Recording cannot be performed with camera set
to this item.
Pressing the WARNING RESET button while the
cursor is on the left of the desired camera number
changes that cameras PPS and A-PPS to - - - - - -.
For details concerning normal recording settings,
see Setting the recording interval and recording
picture quality for normal recording pages 23, 24.
12. Display the desired item to set and turn the SHUTTLE
ring clockwise.
The setting is confirmed and flashing stops.
13. Turn the JOG dial clockwise to reverse display the
GRADE setting and turn the SHUTTLE ring clockwise.
The background of the GRADE display changes to red
and flashes.
Setting of GRADE ( default : STD )
SUPER, HIGH, STD(STANDARD), BASIC, LONG
14. Display the desired item to set and turn the SHUTTLE
ring clockwise.
The setting is confirmed and flashing stops.
15. (When setting recording intervals and recording picture
quality for alarm recording )
Repeat steps 11 ~ 14 and select desired settings for A-PPS
and A-GRADE as well.
16. When the setting is complete, turn the SHUTTLE ring
counterclockwise.
The cursor moves to the camera number directly to the left.
17. When continuing with other camera number, turn the JOG
dial to move the cursor to the desired camera number and
repeat steps 11 ~ 16 for settings.
18. When completed with all settings, turn the SHUTTLE ring
counterclockwise or press the SET UP button.
PRE ALARM REC
The pre-alarm recording can be set.
10
11
13
14
15
16
12
1
.
563P
STD
1
.
563P
STD
PRE ALARM REC ( S ) S
SHUTTLE<<:BACK
<ESTD REC> D H M
Setting ( default : 0S )
0S, 1S, 2S, ,58S, 59S, 60S, 90S,
120S, 150S, 180S
When 0S is selected, the pre-alarm recording
is inoperable.
The maximum pre-alarm recordable time is dis-
played in ( ). Beware that when set the pre-alarm
recording time longer than the maximum the set-
tings will turn red. Set the time within the recording
time limit, so that the display returns to white. Even
if the time is set beyond the limit, Pre-Alarm record-
ing time is not changed.
1. Press the SET UP button
}
<SETTINGS>
}
<RECORD
SETTINGS>
}
Select PRE ALARM REC in the <RECORD
SETTING> 2/2 screen, and display the desired setting.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
Page view 43