Mitsubishi Electric DX-TL2500E Instruction Manual Page 73

  • Download
  • Add to my manuals
  • Print
  • Page
    / 106
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 72
73
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Operations
ENGLISH
<ALARM SKIP SEARCH>
>>
EXECUTE(FORWARD)
EXECUTE(REVERSE)
PUSH SEARCH KEY FOR
SEARCH SELECTION
To change the desired camera number to the single screen dis-
play during still-frame playback in SPLIT16 display, press the SEARCH
button to clear the search setting screen and press the desired cam-
era number button.
Search may not perform properly at times depending on the re-
corded condition of the index signals.
ALARM SKIP SEARCH
This function searches up to where the Alarm recording signal is located,
and can playback at 4 second intervals.
<ALARM SKIP SEARCH> In the case of forward direction
SKIP COUNT
0302
01
Alarm
Recording
Alarm
Recording
Alarm
Recording
Index signalIndex signalIndex signal
Search SearchSearch Search
Present position
Approx. 4 sec.
play
Approx. 4 sec.
play
Approx. 4 sec.
play
1. Press the SEARCH button.
The search screen selected in the SEARCH TYPE ( see page 71 ) appears.
2. (When the desired search screen is not displayed on the screen )
Change the above SEARCH TYPE setting and display the ALARM SKIP
SEARCH screen.
3. Select EXECUTE(FORWARD) or EXECUTE(REVERSE) and confirm.
EXECUTE(FORWARD) : Search is performed in the forward direction.
EXECUTE(REVERSE) : Search is performed in the reverse direction.
To cancel the search, press the SEARCH button twice.
Playback of search result from skip search will be in SPLIT16 display regardless
of whether the SELECTION CAMERA NUMBER ( see page 71 ) is set to
ALL or individual camera number is selected.
To return to the normal screen, press the SEARCH button twice.
Press the desired camera number button when performing skip
search in SPLIT16 display, the video of the camera number button is
changed to single screen display.
4. Press the PAUSE button when the desired video is displayed and press the
PLAY button.
5. To stop ALARM SKIP SEARCH, press the STOP button.
6. To clear the search screen, press the SEARCH button twice.
When performing skip search in the reverse direction with index
signals of less than 4 seconds, that portion may play back repeat-
edly. In this case, press the STOP button to stop the search and
perform skip search in the reverse direction again after the particular
portion has been passed using reverse playback, etc.
Search may not perform properly at times depending on the re-
corded condition of the index signals.
Page view 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 105 106

Comments to this Manuals

No comments