4-3. LOCKING THE OPERATION MODE OF THE AIR CONDITIONER (COOL, DRY, HEAT)
4-4. LOWERING THE OPERATION NOISE OF THE OUTDOOR UNIT
4-2. GAS CHARGE
Perform gas charge to unit.
1)Connectgascylindertotheserviceportofstopvalve.
2)Performairpurgeofthepipe(orhose)comingfromrefrigerantgascylinder.
3)Replenish speciedamount of therefrigerant, whileoperating the aircondi
-
tioner for cooling.
Note:
Incaseofaddingrefrigerant,complywiththequantityspeciedfortherefrigerat
-
ingcycle.
CAUTION:
Whenchargingtherefrigerantsystemwithadditionalrefrigerant,besuretouse
liquidrefrigerant.Addinggasrefrigerantmaychangethecompositionofthe
refrigerantinthesystemandaffectnormaloperationoftheairconditioner.Also,
chargethesystemslowly,otherwisethecompressorwillbelocked.
Tomaintainthehighpressureofthegascylinder,warmthegascylinderwith
warmwater(under40°C)duringcoldseason.Butneverusenakedreorsteam.
Lower the operating
noise
HEAT
COOL/DRY
• Descriptionofthefunction:
Withthisfunction,youcanlocktheoperationmodeoftheoutdoorunit.Once
the operation mode is locked to either COOL/DRY mode or HEAT mode, the
airconditioneroperatesinthatmodeonly.
* Initial setting is required to activate this function. Please explain about this
functiontoyourcustomersandaskthemwhethertheywanttouseit.
[How to lock the operation mode]
1) Be sure to turn off the main power for the air conditioner before making the
setting.
2) Set the 1st Dip Switch of SW1 on the outdoor controller board to ON to en
-
able this function.
3) To lock the operation mode in COOL/DRY mode, set the 2nd Dip Switch of
SW1 on the outdoor controller board to OFF. To lock the operation in HEAT
mode, set the same switch to ON.
4) Turn on the main power for the air conditioner.
• Descriptionofthefunction:
Withthisfunction,youcanlowertheoperatingnoiseoftheoutdoorunitwhen
the operation load is small, for example, during nighttime in COOL mode.
However,pleasenotethatthecoolingandheatingcapacitycanalsobelow
-
ered if this function is activated.
* Initial setting is required to activate this function. Please explain about this
functiontoyourcustomersandaskthemwhethertheywanttouseit.
[How to lower the operating noise]
1) Be sure to turn off the main power for the air conditioner before making the
setting.
2) Set the 3rd Dip Switch of SW1 on the outdoor controller board to ON to en
-
able this function.
3) Turn on the main power for the air conditioner.
Union
Stop valve
Liquid
pipe
Indoor
unit
Stop valve with
service port
Gas
pipe
Refrigerant gas
cylinder
operating valve
(for R410A)
Gauge manifold
valve (for R410A)
Charge hose
(for R410A)
RefrigerantgascylinderforR410Awithsiphon
Electronic scale for refrigerant charging
Refrigerant (liquid)
Outdoor
unit
*Eunitisfor
5B100VAonly.
Union
Union
Union
4-5. CHANGING THE AMPERE LIMIT
• Descriptionofthefunction:
Withthisfunction,youcanchangethecurrentthatowsintheoutdoorunit.
Note:
Usethisfunctiononlywhentheamountofcurrentexceedstheallowedvalue.
[How to change the ampere limit]
1) Be sure to turn off the main power for the air conditioner before making the
setting.
2) Make the setting referring to the table below.
3) Turn on the main power for the air conditioner.
SW2 MXZ-5B100VA MXZ-4B80VA
10.5 A 10.5 A
15.5 A 15.5 A
Factorysetting
Full
Factorysetting
Full