30
10-7.TEST POINT DIAGRAM
Indoor controller board
PLA-RP35/50/60/71/100/125/140BA.UK
PLA-RP35/50/60/71BA
1.UK
PLA-RP30/50/60/71/100/125/140BA#2.UK
PLA-RP71/100/125/140BA2.UK
CN3C
Transmission
(Indoor/outdoor)
(0~24V DC)
SW2
Capacity setting
SW1
Model selection
CN2L
Connector (LOSSNAY)
CN41
Connector
(HA terminal-A)
CN90
Connect to the wireless
remote controller board
(CNB)
CN20
Room temperature
thermistor (TH1)
CN22
Connect to the terminal
block (TB5)
(Remote controller con-
necting wire)
(10.4~14.6V DC)
LED2
Power supply (R.B)
LED1
Power supply (I.B)
LED3
Transmission (Indoor/outdoor)
CNP
Drain-pump output (DP)
(220-240V AC)
CN01
Connect to the Terminal Block (TB4)
(Indoor/outdoor connecting line)
Between 3 and 5
220-240V AC
CN3G
Connect to the auto grille controller board (CN3G)
13V pulse output
CNV
Vane motor output (MV)
12V pulse output
SWE
Emergency operation
Jumper wire J41,J42
Pair No. setting for wireless
remote controller
FUSE 6.3A /250V
CNAC
Connect to the auto grille
controller board (CN3A)
(220-240V AC)
CNMF
Fan motor
1-4: DC 310~340V
5-4: DC15V
V
CC
: Voltage between pins of
C955 15VDC
(Same as 5(+)–4(-) of CNMF)
CN44
Pipe temperature
thermistor
1-2 : Liquid (TH2)
3-4 :
Condenser/Evaporator(TH5)
CN4F
Drain float switch (FS)
CN4Y
i-see sensor
CN6Y
i-see sensor motor output
12V DC pulse output
CN32
Connector
(Remote switch)