SW2 setting
Display detail
Explanation for display
Unit
1
ON
23456
Comp.surface temperature (TH34)
-52 – 221
-52 – 221
(When the comp.shell thermistor detects 100°C or
more, hundreds digit, tens digit and ones digit are
displayed by turns.)
(Example) When 105°C;
0.5 secs. 0.5secs. 2 secs.
05
1
:
The black square ( ) indicates a switch position.
1
ON
23456
(No error)
Overvoltage error
Undervoltage error
Input current sensor error
Abnormal power synchronous signal
PFC error
(Overvoltage / Undervoltage / Overcurrent)
PFC/ IGBT error
(Undervoltage)
* Display examples for multiple errors:
Overvoltage (01) + Undervoltage (02) = 03
Undervoltage (02) + Power-sync signal error (08) = 0A
Input current sensor error (04) + PFC error (10) = 14
Description Display
00
01
02
04
08
10
20
U9 Error details (To be shown while
error call is deferred.)