VECTOR CONTROL
31
6
6.2 Specifications
Regeneration unit (option) is necessary for regeneration
With online auto tuning (adaptive magnetic flux observer), dedicated motor, rated load
Speed control
Speed control range 1:1500 (both driving/regeneration )
Speed variation ratio ±0.01% (100% means 3000 r/min)
Speed response 130 Hz
Maximum speed 120 Hz (102400 pulse/s or less encoder pulses)
Torque c o n t r o l
Torque control range 1:50
Absolute torque accuracy ±10%
Repeated torque accuracy ±5%
Position control
Repeated positioning
accuracy
±1.5° (at motor shaft end)
Maximum input pulse
frequency
100 kpps (Terminal JOG)
Positioning feedback
pulse
Number of encoder pulses per motor rotation (Pr.369) 4
Electronic gear setting 1/50 to 20
In-position width 0 to 32767 pulses
Error excess 0 to 400k pulses
Function
• Setting of speed feedback range
• Setting of feedback gain
• Setting of encoder rotation direction