Mitsubishi Electric MUX-A20WV Service Manual Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
29
LA
Indoor unit A
H L
B H
Indoor unit B
Outdoor unit
MUX-2A70VB - E1
UNIT No.
Insulation
thickness
Pipe
For liquid
For gas
Outside diameter
mm
6.35
9.52
8mm
8mm
and unit
BA
Insulation material
Heat resisting foam plastic
0.045 specific gravity
Outdoor unit
precharged
950g
Refrigerant piping length (one way)
unit
B
Outdoor unit
precharged
950g
Refrigerant piping length (one way)
7m
0
8m
20
9m
40
10m
60
11m
80
12m
100
13m
120
14m
140
15m
160
ADDITIONAL REFRIGERANT CHARGE (R410A:g)
PIPING PREPARATION
1Table below shows the specifications of pipes commercially available.
2Ensure that the 2 refrigerant pipes are well insulated to prevent condensation.
3Refrigerant bending radius must be 10cm or more.
MAX.REFRIGERANT PIPING LENGTH & MAX. HEIGHT DIFFERENCE
unit
A
Max.
limits
UNIT No.
A
B
Pipe length
15m
15m
LA
LB
Height difference (H)
10m
10m
No. of bends
10
10
7m
0
8m
20
9m
40
10m
60
11m
80
12m
100
13m
120
14m
140
15m
160
OB384--1.qxp 05.1.17 13:08 Page 29