Mitsubishi Electric MUX-A20WV Service Manual Page 66

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 65
66
OPERATING PROCEDURE PHOTOS
2. Removing the relay panel
(1) Remove the cabinet. (Refer to 1.)
(2) Disconnect the following connectors.
.
Outdoor fan motor
.
Only MUX-3A60VB and MUX-3A63VB
Solenoid coil (21RB, 21R3, 21R4)
.
Only MUX-4A73VB
Solenoid coil (21RA, 21RB, 21R1, 21R2, 21R3, 21R4)
3. Removing the propeller
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the propeller nut.
(3) Remove the propeller.
NOTE : Loose the propeller in the rotating direction for
removal.
When attaching the propeller, align the mark on the
propeller and the motor shaft cut section.
Set the propeller in position by using the cut on the
shaft and the mark on the propeller.
4. Removing the outdoor fan motor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the propeller. (Refer to 3.)
(3) Remove the clamp of outdoor fan motor lead wire and
disconnect the outdoor fan motor connector.
(4) Remove the screws fixing the outdoor fan motor.
(5) Remove the outdoor fan motor.
Photo 4
Solenoid coil connector
(21RA, 21RB, 21R1,
21R2, 21R3, 21R4)
Screws of
the relay
panel
Outdoor fan
motor connector
Screws of the
relay panel
Clamp
Screws of the
outdoor fan motor
Outdoor
fan
motor
Propeller
Propeller nut
Back panel
OB384--3.qxp 05.1.17 13:10 Page 66