Mitsubishi Electric FR-A5NR Instruction Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 57
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
9
Settings
FUNCTIONS
2
2.2 Settings
When you press the [OK] button on the initial screen, the following screen appears:
(1) Menu list
This software has the following functions:
Menu Pull-Down Menu Function/Operation
File
(Alt+F)
O
pen Ctrl+O Opens a file.
C
lose Closes the screen.
S
ave Ctrl+S Saves data.
Save A
s Ctrl+A Save data with a new name.
P
rint Ctrl+P Selects printing.
Ex
it Performs exiting procedure.
S
ettings
(Alt+S)
S
ystem Settings Sets the model, capacity (size) and option type. (Stations 00 to 31)
Communicat
ion Settings Sets serial communication information.
E
nvironmental Settings
Sets the directory where data will be stored and sets re-display of the initial
screen.
P
arameter
(Alt+P)
A
ll list Format Shows and sets the parameter list.
F
unctional List Format Shows and sets the related parameters function-by-function.
I
ndividual list Format
You can register or delete a total of 32 parameters out of all parameters to
or from two different user groups.
B
asic Settings
You can set the parameters required for starting up the inverter without
being aware of parameter numbers.
M
onitor
(Alt+M)
D
ata Display Shows four pieces of data (up to four stations) in terms of values.
M
eter Display Shows four pieces of data (up to four stations) in terms of meter deflections.
O
scilloscopes Shows four pieces of data (up to four stations) in terms of waveforms.
A
larm History Shows the alarm history of all inverter stations connected.
T
race Oscilloscopes Analyzes various types of data.
Diagn
osis
(Alt+N)
V
FD Status Shows various data of all stations connected in real time in terms of values.
D
iagnosis
Examine the estimated cause of the alarm in accordance with the alarm
display.
T
est Running
(Alt+T)
T
est Running
Gives the operation command from the personal computer to actually test
run the inverter.
A
uto Tuning
Performs auto tuning in accordance with the motor connected to the
inverter.
Adv
anced function
(Alt+V)
M
achine Analyzer
Measures the response frequency characteristic of speed relative to the
motor torque of the machine.
W
indow
(Alt+W)
C
ascade Display Overlapping Windows.
T
ile Display Windows are side-by-side.
H
elp
(Alt+H)
C
ontents Various help functions (parameter explanations, function explanations, etc.)
About VFD Setup S/W
Version information (copyright, version information, user and company
names, etc.)
1)
5)
6) 7)
2) 3) 4)
8)
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 56 57

Comments to this Manuals

No comments