Mitsubishi Electric FR-A5NR Instruction Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 57
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
27
Monitor
FUNCTIONS
2
(2) Trace function setting screen
By changing the set values on the trace function setting screen and writing them to the parameters, you can
change the parameter settings of the inverter. (Refer to page 28 for details of the parameters.)
Trace function setting screen
1) Function setting [Pr. 520 to Pr. 529]
Select the data of CH1 to CH10. The selected data are displayed.
You can assign one piece of data to two or more channels.
Selecting the data changes the Pr. 520 to Pr. 529 values.
2) Sample Ti
me [Pr. 530]
Vary the sampling period. (1 = 444s)
Varying the sampling period changes the Pr. 530 value.
3) Sample M
ode [Pr. 531]
Set the number of samplings made at one time. Increasing the sampling count limits the number of data that
can be traced.
Changing the sampling mode changes the Pr. 531 value.
4) T
rigger Signal 1 [Pr. 532]
A specific signal times the start and end of a trace.
Changing the trigger signal choice 1 changes the Pr. 532 value.
5) Trig
ger Signal 2 [Pr. 533]
When you have selected "Error (trigger signal choice 2)" in the trigger signal choice 1, select the error that
will output a trigger signal.
Changing the trigger signal choice 2 changes the Pr. 533 value.
6) Trigger L
evel [Pr. 534]
A trigger is enabled when the value of the data set in the trigger signal choice 1 reaches the set trigger level
on the trigger condition.
Changing the trigger level changes the Pr. 534 value.
7) Trigger conditions [Pr. 535]
Select whether a trigger will be enabled on the "leading edge" or on the "trailing edge".
Changing the trigger condition changes the Pr. 535 value.
8) P
re-trigger [Pr. 536]
Used to trace the data before trigger.
Specify the percentage of the trigger point on the assumption that the recording starting point is 0% and the
recording end point is 100%.
Changing the pre-trigger changes the Pr. 536 value.
9) V
iew Parameter
Clicking [View Parameter] shifts to the parameter check screen.
10) Cancel
Clicking [Cancel] cancels function changing and returns to the trace function oscilloscope screen.
CAUTION
The trace function setting screen is used to only set the parameter values and not to write them. Use the
parameter check screen to write them. Click [Parameter check]. (Refer to page 32 for details of the
parameter check screen.)
1)
4
)
5)
6)
8)
7)
3)
2)
10)
9)
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 56 57

Comments to this Manuals

No comments

Extron electronic MSW 4V rs manuals

Owner’s manuals and user’s guides for Computer Accessories Extron electronic MSW 4V rs.
We providing 1 pdf manuals Extron electronic MSW 4V rs for download free by document types: User Manual






More products and manuals for Computer Accessories Extron electronic

Models Document Type
MMX VGA Series User Manual   Extron electronic MMX VGA Series User Manual, 4 pages
MLS 103 V User Manual   Extron electronic MLS 103 V User Manual, 25 pages
MTPX Plus Series User Manual   Extron electronic MTPX Plus Series User Manual, 4 pages
P/N 68-424-02 User Manual   Extron electronic P/N 68-424-02 User Manual, 5 pages
System 5 IP Series User Manual   Extron electronic System 5 IP Series User Manual, 3 pages
TPR150 User Manual   Extron electronic TPR150 User Manual, 1 pages
MediaLink Controllers MLC 206 User Manual   Extron electronic MediaLink Controllers MLC 206 User Manual, 4 pages
IP Link IPL T SF2 User Manual   Extron electronic IP Link IPL T SF2 User Manual, 6 pages
MTPX 816 User Manual   Extron electronic MTPX 816 User Manual, 4 pages
ISS 408 User Manual   Extron electronic ISS 408 User Manual, 3 pages
System 8 Plus User Manual   Extron electronic System 8 Plus User Manual, 3 pages
GB 190F User Manual   Extron electronic GB 190F User Manual, 3 pages
ISM 482 User Manual   Extron electronic ISM 482 User Manual, 105 pages
819 60-190-01 User Manual   Extron electronic 819 60-190-01 User Manual, 1 pages
IPI 201 AAP User Manual   Extron electronic IPI 201 AAP User Manual, 2 pages
3000 User Manual   Extron electronic 3000 User Manual, 2 pages
FOX 4G SW8 User Manual   Extron electronic FOX 4G SW8 User Manual, 2 pages
6400s User Manual   Extron electronic 6400s User Manual, 70 pages
MSG Series User Manual   Extron electronic MSG Series User Manual, 3 pages
DXP 44 SDI User Manual   Extron electronic DXP 44 SDI User Manual, 2 pages