GT Works
External
dimensions
Specifications
Connection
configuration
Bus
connection
P.30
~
GOT
dictionary
P.32
~
P.42
~
P.36
~
P.50
~
Features and
recommended points
A985GOT-V
A975GOT
A970GOT
A970GOT
A960GOT
A985GOT
A956WGOT
Options
P.6
~
P.4
~
P.2
~
P.8
~
P.10
~
P.12
~
P.16
~
P.18
~
P.20
~
P.22
~
P.24
~
P.26
~
P.28
~
P.40
~
Connectable
model list
P.52
~
P.54
~
Notes
for use
P.56
~
List of
products
P.57
~
Function list
for each model
Concept Lineup
Special report
GT SoftGOT
Special report
Gateway functions
Special report
Servo-related functions
A95 GOT
Introduction
6 7
Servo-related functions
Special
report 1
Special
report 1
Motion monitor function enables the connection with
Q172CPU/Q173CPU on multi PLC system.
: Available : Not available
• Use the following versions of the motion controller CPU (Q Series).
1) Products with the main unit OS of Version 00E
2) Products whose main units have the following serial numbers (indicated on the rating plate on the CPU module side)
Q172CPU : serial numbers K
xxxxx
, Q173CPU : serial numbers J
xxxxx
• An extension memory board should be installed in GOT for A985GOT, A975GOT, A970GOT, A960GOT, A956WGOT.
• Type A95*GOT-M3 (built-in memory extension type) is required for A95*GOT.
• In a multi PLC system, PLC No.1 must be a Q Series PLC CPU. Also, install the Q172CPU/Q173CPU on the right side
of the Q Series PLC CPU on the main base.
• Functions except above (i.e. Jog operation, Servo test etc.) are not available for motion monitor function.
• The following connection methods are available for Q172CPU/Q173CPU.
Note: The Q172CPU/Q173CPU can only be monitored on the same base, and not on other stations.
Bus connection
CPU direct connection
Computer link connection
MELSECNET connection
CC-Link connection Ethernet connection
Current value
SFC error history
Error list
Error list (Specified Axis)
Positioning monitor
Servo monitor
Current value history
*1
Servo monitor (Basic parameter, adjustment parameter)
*2
Servo monitor
Parameter setting
Function
Install the extended function OS
from GT Designer to the GOT to
use this function.
Switch the screens from the utility screen
or with a touch key from the GOT.
Motion monitoring and
parameter setting utility screen.
Personal computer
GOT
PLC
(Multi PLC system)
PULL
USB
Q02HCPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
POWER
Q61P-A1
USB
Q172CPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
CN2
CN1
FRONT
SSCNET
USB
Q172CPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
CN2
CN1
FRONT
SSCNET
USB
Q172CPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
CN2
CN1
FRONT
SSCNET
SY. ENC1
SY. ENC1
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Q172Q172
Q172EX
SY. ENC TREN
QX40
1
2
1
2
A985GOT(-V)
*1
A975GOT
*1
A970GOT
*1
A960GOT
*1
A956WGOT
*1
A95 GOT-M3
*2
Install the servo monitoring
extended function OS and special
monitor data from GT Designer to
the GOT to use this function.
Switch the screens from the utility screen
or with a touch key from the GOT.
Up to 32 servo system controllers
(stations 0 to 32) can be monitored.
• MELSERVO-J2-Super series (MR-J2S A series, MR-J2S- CP series)
• MELSERVO-J2M A series (MR-J2M- DU (drive unit))
• MR-J2M-P8A (interface unit)
Connect to the RS-232C
interface of the GOT.
Personal computer
GOT
RS-232C cable RS-422 cable
*4
Servo system
controllers
PLC
Servo amplifier monitor function
Function
1
1
Motion monitor function
Function
2
2
Motion controller (Q series) monitoring and setting
parameters can be done from the GOT.
Special module monitor function
Function
3
3
Monitoring/changing buffer memory data for QD75M
can be done from the GOT.
Motion
monitor
function
This function allows you to monitor and
set parameters for Q series motion
controller (Q172CPU/Q173CPU) from
the GOT. You can monitor up to 3
motion controllers (Q172CPU/Q173CPU)
and set the parameters of them on the
same base.
Function list
Available Servo Amplifiers
Available GOT
Connection type list
You can adjust servo amplifiers or read the servo amplifier error history using a GOT,
without having the need for a separate peripheral device on-site.
PULL
USB
PULL
Q25HCPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
POWER
Q61P-A1
QJ71C24
QJ71C24
QX10
QX10
QJ71LP21-25
Servo motors,
etc.
*1: The servo amplifier monitor function cannot be used with the
barcode function or transparent function.
*2: The communication speed with the servo system controller
is up to 38400bps.
*3: Any data set by the servo monitor function will not save as a file.
*4: Signal converters are required for multi-drop connection.
*1 The extension memory board A9GT-FNB(1/2/4/8M) or A9GT-QFNB(4/8M) is required
*2 Only the A95 GOT-M3 (built-in memory extension type) is available.
NEWNEW
NEWNEW
*1: Current value history monitor is not compatible with A95*GOT
*2: Use MR-J2S servo amplifier version B1 or later for parameter setting function.
*4
*4