MITSUBISHI ELECTRIC EUROPE B.V.MITSUBISHI ELECTRIC EUROPE B.V.MELSEC System QProgrammable Logic ControllersUser's ManualHART Analog Output Module
ContentsVI3.5.6 Short circuit detection setting (Un\G45) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-343.5.7 Rate control enab
Programming Example 2: ME1DA6HAI-Q used in Remote I/O Network5 – 205.3.3 Program● Remote I/O station status check Fig. 5-17: Status checking of the re
Example 2: ME1DA6HAI-Q used in Remote I/O Network ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 21● Initial settings Fig. 5-18: Initial setting
Programming Example 2: ME1DA6HAI-Q used in Remote I/O Network5 – 22● Communication with HART devicesThe following part of the program is optional. If
Example 2: ME1DA6HAI-Q used in Remote I/O Network ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 23● Writing of digital values and analog output
Programming Example 2: ME1DA6HAI-Q used in Remote I/O Network5 – 24● Disconnection detection status and processing at disconnection detection Fig. 5-2
Example 2: ME1DA6HAI-Q used in Remote I/O Network ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 25● Short circuit detection status and processi
Programming Example 2: ME1DA6HAI-Q used in Remote I/O Network5 – 26● HART field device status check and processing at device malfunction Fig. 5-25: HA
Error Code List TroubleshootingHART Analog Output Module ME1DA6HAI-Q 6 – 16 TroubleshootingThe following section explains the types of errors that may
Troubleshooting Troubleshooting using the LEDs of the Module6 – 26.2 Troubleshooting using the LEDs of the Module6.2.1 When the "RUN" LED
When an Analog Output Value is Not Output TroubleshootingHART Analog Output Module ME1DA6HAI-Q 6 – 36.3 When an Analog Output Value is Not Output6.4
ContentsHART Analog Output Module ME1DA6HAI-Q VII5 Programming5.1 Programming Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting Checking the Analog Output Module Status6 – 46.5 Checking the Analog Output Module StatusWhen the analog output module detail informa
Checking the Analog Output Module Status TroubleshootingHART Analog Output Module ME1DA6HAI-Q 6 – 5Contents of Module‘s Detailed Information● Module–
Troubleshooting Checking the Analog Output Module Status6 – 6
IndexHART Analog Output Module ME1DA6HAI-Q IIndexAAccuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5ALM L
IIIndexCommunication enable/disable setting . . . . . . 3-38Device variable status . . . . . . . . . . . . . . . . . . . . . . . . 3-42Extended field
HEADQUARTERSEUROPEMITSUBISHI ELECTRIC EUROPE B.V.German BranchGothaer Straße 8D-40880 RatingenPhone: +49 (0)2102 / 486-0Fax: +49 (0)2102 / 486-1120CZE
ContentsVIII
Features OverviewHART Analog Output Module ME1DA6HAI-Q 1 – 11 OverviewThis User's Manual describes the specifications, handling and programming m
Overview Features1 – 2Disconnection detection functionWhen the analog output current is 4mA or more, the voltage across the output is watched to detec
Applicable Systems System ConfigurationHART Analog Output Module ME1DA6HAI-Q 2 – 12 System Configuration2.1 Applicable SystemsApplicable modules, base
System Configuration Applicable Systems2 – 2● Mounting to a MELSECNET/H remote I/O stationThe table below shows the network modules and base units app
Applicable Systems System ConfigurationHART Analog Output Module ME1DA6HAI-Q 2 – 3Supported software packagesRelation between the system containing th
System Configuration How to Check the Function Version and Serial No. of the Modules2 – 42.2 How to Check the Function Version and Serial No. of the
Part Names Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 13 Detailed Description of the Module3.1 Part NamesThis section
Detailed Description of the Module Part Names3 – 23.1.1 Signal Layout of the Terminal BlockFor the wiring of the HART analog output module ME1DA6HAI-
Specifications Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 33.2 SpecificationsThe specifications for the ME1DA6HAI-Q a
Detailed Description of the Module Specifications3 – 43.2.1 I/O conversion characteristicsThe I/O conversion characteristics are used for converting t
Specifications Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 53.2.2 AccuracyThe reference accuracy is the accuracy relat
Detailed Description of the Module Functions of the HART Analog Output Module3 – 63.3 Functions of the HART Analog Output Module3.3.1 Analog output
Functions of the HART Analog Output Module Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 7*1 A watchdog timer error occ
Detailed Description of the Module Functions of the HART Analog Output Module3 – 83.3.2 Analog output test during PLC CPU STOPDuring the programmable
Functions of the HART Analog Output Module Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 9Example:– Output range: 0 to 2
Detailed Description of the Module Functions of the HART Analog Output Module3 – 103.3.4 Scaling functionThe scaling function can be enabled individua
Functions of the HART Analog Output Module Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 113.3.5 Warning output functio
About this ManualThe texts, illustration, diagrams and examples in this manual are provided for informationpurposes only. They are intended as aids to
Detailed Description of the Module Functions of the HART Analog Output Module3 – 123.3.6 Disconnection detection functionWhen the output voltage incr
Functions of the HART Analog Output Module Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 133.3.7 Short circuit detectio
Detailed Description of the Module Functions of the HART Analog Output Module3 – 143.3.8 HART Master FunctionWhat is HART? HART stands for Highway Ad
Functions of the HART Analog Output Module Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 15cation (in this case the ME1D
Detailed Description of the Module I/O Signals for the Programmable Controller CPU3 – 163.4 I/O Signals for the Programmable Controller CPU3.4.1 Lis
I/O Signals for the Programmable Controller CPU Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 173.4.2 Details of I/O si
Detailed Description of the Module I/O Signals for the Programmable Controller CPU3 – 18Device No. Signal Name DescriptionXF Error flag The error fla
I/O Signals for the Programmable Controller CPU Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 19Output signalsDevice No.
Detailed Description of the Module Buffer Memory3 – 203.5 Buffer MemoryThe HART analog output module has a memory range assigned as a buffer for tempo
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 213.5.1 Buffer memory assignment* Indicates whether readin
Detailed Description of the Module Buffer Memory3 – 22* Indicates whether reading from and writing to a sequence program are enabled. R : Read enabl
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 23* Indicates whether reading from and writing to a sequenc
Detailed Description of the Module Buffer Memory3 – 24* Indicates whether reading from and writing to a sequence program are enabled. R : Read enabl
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 25* Indicates whether reading from and writing to a sequenc
Detailed Description of the Module Buffer Memory3 – 26* Indicates whether reading from and writing to a sequence program are enabled. R : Read enabl
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 27* Indicates whether reading from and writing to a sequenc
Detailed Description of the Module Buffer Memory3 – 28* Indicates whether reading from and writing to a sequence program are enabled. R : Read enabl
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 29Indicates whether reading from and writing to a sequence p
Detailed Description of the Module Buffer Memory3 – 30* Indicates whether reading from and writing to a sequence program are enabled. R : Read enabl
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 31* Indicates whether reading from and writing to a sequenc
HART Analog Output ModuleME1DA6HAI-QUser's ManualArt.-no.: 236882Version Changes / Additions / CorrectionsA 08/2010 pdp-dk First edition
Detailed Description of the Module Buffer Memory3 – 323.5.2 CH digital value (Un\G1 to Un\G6)● This area is used by the programmable controller CPU t
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 333.5.3 CH set value check codes (Un\G11 to Un\G16)● Digita
Detailed Description of the Module Buffer Memory3 – 343.5.6 Short circuit detection setting (Un\G45)● Thi s area is use d to define whether to enabl
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 353.5.8 Disconnection detection/warning output setting (Un\
Detailed Description of the Module Buffer Memory3 – 363.5.10 Disconnection detection flags (Un\G49)● If a disconnection occurs while an output of 4 m
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 373.5.12 Scaling enable/disable setting (Un\G53)● Whether t
Detailed Description of the Module Buffer Memory3 – 383.5.15 CH Warning output upper/lower limit values (Un\G86 to Un\G97)● Set the upper and lower l
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 39 When a HART device is detected, the device information i
Detailed Description of the Module Buffer Memory3 – 403.5.19 HART maximum retries (Un\G176 to Un\G181)● Set the maximum number of command retries for
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 41Whether the bits b8 to b14 store information about a commu
Detailed Description of the Module Buffer Memory3 – 423.5.23 Device variable status (Un\G242 & Un\G243, Un\G254 & Un\G255...)● The status of
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 433.5.24 HART process variables (Un\G244 to Un\G251, Un\G25
Detailed Description of the Module Buffer Memory3 – 443.5.25 HART Command Request (Un\G352 to Un\G483)HART Command Request Flag (Un\G352)● For execut
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 45HART Command Request Channel (Un\G353)● Un\G353 contains t
Detailed Description of the Module Buffer Memory3 – 463.5.26 HART Command Answer (Un\G496 to Un\G627)HART Command Answer Flag (Un\G496)● The high byt
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 473.5.27 Information about HART Device (Un\G896 to Un\G966,
Detailed Description of the Module Buffer Memory3 – 48Hart Device Type● The Hart Device Type is set by the manufacturer and read by HART Command #0.●
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 49HART Device Function Flags● The HART Device Function Flags
Detailed Description of the Module Buffer Memory3 – 50HART Final Assembly Number ● The HART Final Assembly Number is read by HART Command #16.● Two su
Buffer Memory Detailed Description of the ModuleHART Analog Output Module ME1DA6HAI-Q 3 – 51HART PV Upper and Lower Range Value● The upper and lower r
HART Analog Output Module ME1DA6HAI-Q ISafety GuidelinesFor use by qualified staff onlyThis manual is only intended for use by properly trained and q
Detailed Description of the Module Buffer Memory3 – 52
Handling Precautions Setup and Procedures before OperationHART Analog Output Module ME1DA6HAI-Q 4 – 14 Setup and Procedures before Operation4.1 Handli
Setup and Procedures before Operation Setup and Procedures before Operation4 – 24.2 Setup and Procedures before Operation Fig. 4-1: Function chart f
Installation of the Module Setup and Procedures before OperationHART Analog Output Module ME1DA6HAI-Q 4 – 34.3 Installation of the ModuleThe ME1DA6HA
Setup and Procedures before Operation Wiring4 – 44.4 Wiring4.4.1 Wiring precautionsIn order to optimize the functions of the HART analog output module
Wiring Setup and Procedures before OperationHART Analog Output Module ME1DA6HAI-Q 4 – 54.4.2 External wiringThe ME1DA6HAI-Q is designed for current ou
Setup and Procedures before Operation PLC Parameter Setting4 – 64.5 PLC Parameter SettingIn the PLC parameters the I/O assignment for the ME1DA6HAI-Q,
PLC Parameter Setting Setup and Procedures before OperationHART Analog Output Module ME1DA6HAI-Q 4 – 74.5.2 Intelligent function module switch settin
Setup and Procedures before Operation PLC Parameter Setting4 – 8● Setting example:The configuration shown below is used for the setting example.Settin
Setting of the HART Devices Setup and Procedures before OperationHART Analog Output Module ME1DA6HAI-Q 4 – 94.6 Setting of the HART DevicesFor settin
HART Analog Output Module ME1DA6HAI-Q IIGeneral safety information and precautionsThe following safety precautions are intended as a general guidelin
Setup and Procedures before Operation Setting of the HART Devices4 – 10● CommDTM for ME1DA6HAI-QIt can be downloaded from the following web-site:http:
Programming Procedure ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 15ProgrammingThis chapter describes the programs of the HART analog output
Programming Programming Procedure5 – 2 Fig. 5-2: Programming procedure for the ME1DA6HAI-QIs the scalingfunction required?NOYESScaling enable/disable
Example 1: ME1DA6HAI-Q combined with PLC CPU ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 35.2 Example 1: ME1DA6HAI-Q combined with PLC CPUTh
Programming Example 1: ME1DA6HAI-Q combined with PLC CPU5 – 45.2.1 Before creating a programPerform the following steps before creating a program.Wir
Example 1: ME1DA6HAI-Q combined with PLC CPU ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 5Intelligent function module switch settingBased on
Programming Example 1: ME1DA6HAI-Q combined with PLC CPU5 – 6On GX Developer’s or GX IEC Developer’s Parameter setting screen, select the I/O assignme
Example 1: ME1DA6HAI-Q combined with PLC CPU ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 75.2.2 ProgramDevice Function RemarkInputsX0 Module
Programming Example 1: ME1DA6HAI-Q combined with PLC CPU5 – 8● Initial settings Fig. 5-7: The initial settings are performed once when X0 (Module read
Example 1: ME1DA6HAI-Q combined with PLC CPU ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 9● Communication with HART devicesThe following part
ContentsHART Analog Output Module ME1DA6HAI-Q VContents1 Overview1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Programming Example 1: ME1DA6HAI-Q combined with PLC CPU5 – 10● Warning occurrence status and processing at warning occurrence● Disconnection detectio
Example 1: ME1DA6HAI-Q combined with PLC CPU ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 11● Short circuit detection status and processing at
Programming Example 1: ME1DA6HAI-Q combined with PLC CPU5 – 12● HART field device status check and processing at device malfunction Fig. 5-14: HART fi
Example 2: ME1DA6HAI-Q used in Remote I/O Network ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 135.3 Example 2: ME1DA6HAI-Q used in Remote I/
Programming Example 2: ME1DA6HAI-Q used in Remote I/O Network5 – 14● In the event of an error, the error code shall be displayed in BCD format. The e
Example 2: ME1DA6HAI-Q used in Remote I/O Network ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 15Outputs (in main base unit)Y30 to Y3B Error c
Programming Example 2: ME1DA6HAI-Q used in Remote I/O Network5 – 16Internal relaysM1000 Master control instruction for the processing concerning the M
Example 2: ME1DA6HAI-Q used in Remote I/O Network ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 175.3.2 Network parameterNetwork parameter sett
Programming Example 2: ME1DA6HAI-Q used in Remote I/O Network5 – 18 Select MNET/H (Remote-Master) and enter the other items as shown below.The dialog
Example 2: ME1DA6HAI-Q used in Remote I/O Network ProgrammingHART Analog Output Module ME1DA6HAI-Q 5 – 19 When the settings have been made, click End