FR-D700
INSTRUCTION MANUAL (BASIC)
FR-D720-0.1K to 15K
FR-D740-0.4K to 15K
FR-D720S-0.1K to 2.2K
FR-D710W-0.1K to 0.75K
INVERTER
700
4
5
6
7
8
9
3
2
1
CONTENTS
OUTLINE ...................................................................................1
INSTALLATION AND WIRING ...................................................6
PRECAUTIONS FOR USE OF THE INVERTER.........................18
FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER ...20
DRIVE THE MOTOR.................................................................21
PARAMETERS .........................................................................28
TROUBLESHOOTING ..............................................................33
PRECAUTIONS FOR MAINTENANCE AND INSPECTION ........37
SPECIFICATIONS ....................................................................39
Thank you for choosing this Mitsubishi Inverter.
This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.
Please forward this Instruction Manual (Basic) to the end user.
To obtain the Instruction Manual (Applied) and the
Safety stop function instruction manual
Contact where you purchased the inverter, your Mitsubishi sales
representative, or the nearest Mitsubishi FA Center for the following
manuals:
y Instruction Manual (Applied) [IB(NA)-0600366ENG]
y Safety stop function instruction manual [BCN-A211508-000]
These manuals are required if you are going to utilize functions and
performance.
The PDF version of this manual is also available for download at
"MELFANS Web," the Mitsubishi Electric FA network service on the
world wide web (URL: http://www.MitsubishiElectric.co.jp/melfansweb)
1
2
3
4
5
6
7
8
9
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - INVERTER

FR-D700INSTRUCTION MANUAL (BASIC)FR-D720-0.1K to 15KFR-D740-0.4K to 15KFR-D720S-0.1K to 2.2KFR-D710W-0.1K to 0.75KINVERTER700456789321CONTENTSOUTLINE

Page 2 - 4. Additional Instructions

62 INSTALLATION AND WIRINGNOTEyThe life of the inverter is influenced by surrounding air temperature. The surrounding air temperature should be as low

Page 3

7Peripheral devices22.1 Peripheral devicesCheck the inverter model of the inverter you purchased. Appropriate peripheral devices must be selected acco

Page 4 - REMARKS :

8Installation of the inverters and precautions2.2 Installation of the inverters and precautions(1) Installation of the inverterEnclosure surface mount

Page 5 - 1OUTLINE

9Wiring22.3 Wiring2.3.1 Terminal connection diagramNOTEy To prevent a malfunction caused by noise, separate the signal cables more than 10cm from the

Page 6 - 1.2 Operation panel

10Wiring2.3.2 Terminal specificationsTypeTerminalSymbolTerminal Name Terminal SpecificationMain circuit terminalR/L1, S/L2, T/L3 ∗AC power inputConnec

Page 7

11Wiring2* For more details, refer to the Safety stop function instruction manual (BCN-A211508-000). (Please contact your sales representative for the

Page 8

12Wiring2.3.3 Terminal arrangement of the main circuit terminal, power supply and the motor wiringzThree-phase 200V/400V classzSingle-phase 200V class

Page 9 - Setting Description

13Wiring2(1) Wire size and other specifications of the main circuit terminals and the earthing terminalSelect the recommended cable size to ensure tha

Page 10 - 2 INSTALLATION AND WIRING

14WiringThe line voltage drop can be calculated by the following formula:Line voltage drop [V]=Use a larger diameter cable when the wiring distance is

Page 11 - MCCB INV

15Wiring22.3.4 Wiring of control circuit(1) Control circuit terminal layout(2) Wiring methodzWiringUse a blade terminal and a wire with a sheath strip

Page 12 - (2) Environment

A-1This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.Please forward this Instruction Manual (Basi

Page 13 - 2.3 Wiring

16WiringzWire removal(3) Control circuit common terminals (SD, 5, SE)Terminals SD, SE and 5 are common terminals for I/O signals.(All common terminals

Page 14 - ∗ DC reactor connection

17Connection of a dedicated external brake resistor (MRS type, MYS type, FR-ABR) (0.4K or more)22.4 Connection of a dedicated external brake resistor

Page 15 - Terminal

18PRECAUTIONS FOR USE OF THE INVERTER3 PRECAUTIONS FOR USE OF THE INVERTERThe FR-D700 series is a highly reliable product, but incorrect peripheral ci

Page 16 - Single-phase 100V class

19PRECAUTIONS FOR USE OF THE INVERTER3(12) Do not apply a voltage higher than the permissible voltage to the inverter I/O signal circuits.Application

Page 17

204 FAILSAFE OF THE SYSTEM WHICH USES THE INVERTERWhen a fault occurs, the inverter trips to output a fault signal. However, a fault output signal may

Page 18 - (2) Total wiring length

21Start/stop from the operation panel (PU operation)55 DRIVE THE MOTOR5.1 Start/stop from the operation panel (PU operation)5.1.1 Setting the frequenc

Page 19 - (2) Wiring method

22Start/stop from the operation panel (PU operation)5.1.2 Setting the frequency by switches (three-speed setting) (Pr. 4 to Pr. 6)POINTy Use operation

Page 20 - (4) Wiring instructions

23Start/stop from the operation panel (PU operation)55.1.3 Setting the frequency by analog input (voltage input)POINTy Operation panel ( ) is used to

Page 21 - <Example 2>

24Start and stop using terminals (External operation)5.2 Start and stop using terminals (External operation)5.2.1 Setting the frequency by the operati

Page 22

25Start and stop using terminals (External operation)55.2.2 Setting the frequency by switches (three-speed setting) (Pr. 4 to Pr. 6)POINTy To give a s

Page 23

A-2(2) Wiring(3) Trial run(4) Usage(5) Emergency stop(6) Maintenance, inspection and parts replacement(7) Disposalz Do not install a power factor corr

Page 24

26Start and stop using terminals (External operation)5.2.3 Setting the frequency by analog input (voltage input)POINTy Switch ON across terminals STF(

Page 25 - Operation panel

27Start and stop using terminals (External operation)55.2.4 Operating at 60Hz or higher using the external potentiometer< How to change the maximum

Page 26 - [Connection diagram]

28Simple mode parameters6 PARAMETERSSimple variable-speed operation can be performed with the inverter in the initial settings. Set the required param

Page 27

29Parameter list66.2 Parameter listREMARKSy indicates simple mode parameters.y The parameters surrounded by a black border in the table allow its set

Page 28

30Parameter list75Reset selection/disconnected PU detection/PU stop selection0 to 3, 14 to 171477 Parameter write selection 0, 1, 2 078Reverse rotatio

Page 29 - Deceleration

31Parameter list6197 SO terminal function selection0, 1, 3, 4, 7, 8, 11 to 16, 25, 26, 46, 47, 64, 70, 80, 81, 90, 91, 93, 95, 96, 98, 99, 100, 101, 1

Page 30

32Parameter list∗1 Differ according to capacities.6%: 0.75K or less4%: 1.5K to 3.7K3%: 5.5K, 7.5K2%: 11K, 15K∗2 Differ according to capacities. 5s:

Page 31

33Reset method of protective function77 TROUBLESHOOTINGWhen a fault occurs in the inverter, the inverter trips and the PU display automatically change

Page 32 - 6.1 Simple mode parameters

34List of fault displays7.2 List of fault displaysWhen a fault occurs, the inverter trips and the PU display automatically changes to one of the follo

Page 33 - 6.2 Parameter list

35List of fault displays7Fault∗5Overcurrent trip during constant speedAppears when an overcurrent occurred during constant speed operation.y Keep load

Page 34 - Parameter list

A-3<Abbreviation>PU...Operation panel and parameter unit (FR-PU04/FR-PU07)Inverter...

Page 35

36Check first when you have a trouble∗1 Resetting the inverter initializes the internal cumulative heat value of the electronic thermal relay function

Page 36

37Inspection items88PRECAUTIONS FOR MAINTENANCE AND INSPECTIONThe inverter is a static unit mainly consisting of semiconductor devices. Daily inspecti

Page 37 - 7 TROUBLESHOOTING

38Replacement of partsWhen using the safety stop function, periodic inspection is required to confirm that safety function of the safety systemoperate

Page 38 - 7.2 List of fault displays

39Rating99 SPECIFICATIONS9.1 Ratingz Three-phase 200V power supplyz Three-phase 400V power supplyz Single-phase 200V power supplyModel FR-D720-K 0.1

Page 39 - List of fault displays

40Common specificationsz Single-phase 100V power supply∗1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mi

Page 40

41Outline dimension drawings99.3 Outline dimension drawings• Three-phase 200V class• Three-phase 400V class• Single-phase 200V class• Single-phase 100

Page 41 - 8.1 Inspection items

42The EU Directives are issued to standardize different national regulations of the EU Member States and to facilitate freemovement of the equipment,

Page 42 - 8.2 Replacement of parts

43(2) Low Voltage DirectiveWe have self-confirmed our inverters as products compliant to the Low Voltage Directive (Conforming standard EN 61800-5-1)

Page 43 - 9.1 Rating

44∗ Select a UL and cUL certified fuse with Class T fuse equivalent cut-off speed or faster with the appropriate rating forbranch circuit protection,

Page 44 - 9.2 Common specifications

45(Standard to comply with: UL 508C, CSA C22.2 No. 14)1. General precautionThe bus capacitor discharge time is 10 minutes. Before starting wiring or i

Page 45 - Outline dimension drawings

111OUTLINE1.1 Product checking and parts identificationUnpack the inverter and check the capacity plate on the front cover and the rating plate on the

Page 46 - (1) EMC Directive

46REVISIONS*The manual number is given on the bottom left of the back cover. For Maximum Safety• Mitsubishi inverters are not designed or manufactured

Page 47 - Fan cover

International FA CenterKorean FA CenterBeijing FA CenterEuropean FA CenterUK FA CenterCentral and Eastern Europe FA CenterTianjin FA CenterShanghai F

Page 48 - Operation time (s)

HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANMODELMODELCODE1A2-P34FR-D700INSTRUCTION MANUAL (BASIC)IB(NA)-0600438EN

Page 49 - 5. Motor overload protection

2Operation panel1.2 Operation panel1.2.1 Names and functions of the operation panelThe operation panel cannot be removed from the inverter.Operation m

Page 50 - Revision

3Operation panel11.2.2 Basic operation (factory setting)STOPOperation mode switchoverParameter settingFaults history Monitor/frequency settingAt power

Page 51 - International FA Center

4Operation panel1.2.3 Changing the parameter setting valueChanging exampleChange the Pr. 1 Maximum frequency setting.Operation Display 1. Screen at po

Page 52

5Operation panel11.2.4 Parameter clear/all parameter clearPOINTy Set "1" in Pr.CL Parameter clear, ALLC all parameter clear to initialize a