Control circuit specifications
2.3 Control circuit specifications
2.3.1 Control circuit terminal
indicates that terminal functions can be selected using Pr.190 RX2 (terminal Y0) function selection. (Refer to page 167).
(1) Input signal
(2) Output signal
(3) Communication
CC-Link communication can be performed with the CC-Link communication connector.
Type
Terminal
Symbol
Terminal Name Description Rated Specifications
Refer to
Page
24V external power supply
+24 24V external power supply
Even when the main circuit power supply is OFF, CC-
Link communication continues with the input from the
24V external power supply.
Input voltage
23.5 to 26.5VDC
Input current
0.7A or less
23
SD
24V external power supply
common terminal
Com mon ter minal fo r th e term ina l +2 4 --------- ---------
Safety stop function
S1
Safety stop input
(Channel 1)
Terminal S1/S2 are safety stop signals for use with in
conjunction with an approved external safety unit. Both
terminal S1/S2 must be used in dual channel form.
Inverter output is shutoff depending on shorting/
opening between S1 and PC, S2 and PC.
In the initial status, terminal S1 and S2 are shorted with
terminal PC by shorting wire.
Remove the shorting wire and connect the safety relay
module when using the safety stop function.
Input resistance 4.7kΩ
Voltage when contacts
are open
21 to 26VDC
When contacts are short-
circuited
4 to 6mADC
24
S2
Safety stop input
(Channel 2)
PC
Safety stop input terminal
common
Common terminal for safety stop input terminals S1
and S2.
--------- ---------
Type
Terminal
Symbol
Terminal Name Description Rated Specifications
Refer to
Page
Open collector
Y0
Open collector output Y0
(Inverter running)
Switched low when the inverter output frequency is
equal to or higher than the starting frequency (initial
value 0.5Hz). Switched high during stop or DC injection
brake operation.
(Low indicates that the open collector output transistor
is ON (conducts). High indicates that the transistor is
OFF (does not conduct).)
Use Pr. 190 RX2 (terminal Y0) function selection to change
the function assigned to the terminal.
Permissible load 24VDC
(maximum 27VDC) 0.1A
(a voltage drop is 3.4V
maximum when the
signal is ON)
24,
167
SE
Open collector output
common
Commo n te rminal of ter minal Y0. --------- ---------
Type
Connector
Name
Pin Arrangement
Pin
Number
Signal
Name
Communication Connector Plug
Refer
to
Page
CC-Link
CONA
CONB
CONA
CONB
1DA
One-touch connector for CC-Link
communication
52
2DB
3DG
4NC
5SLD
Type
Terminal
Symbol
Terminal Name Description
Refer to
Page
USB
USB connector
The FR Configurator can be operated by connecting the inverter to the personal
computer through USB.
Interface: conforms to USB1.1
Transmission speed: 12Mbps
Connector: USB mini B connector (receptacle mini B type)
220
CONA
CONB
15324
Model Name Manufacturer
A6CON-L5P Mitsubishi Electric Corporation
35505-6000-B0M GF Sumitomo 3M Limited