Parameter listParameter list
92
Parameter List
5
PARAMETERS
244 Cooling fan operation selection 0, 1 1 1 213 244 34 B4 2
Slip
compensation
245 Rated slip 0 to 50%, 9999 0.01% 9999 119 245 35 B5 2 
246 Slip compensation time constant 0.01 to 10s 0.01s 0.5s 119 246 36 B6 2
247
Constant-power range slip
compensation selection
0, 9999 1 9999 119 247 37 B7 2 
249 Earth (ground) fault detection at start 0, 1 1 0 190 249 39 B9 2
250 Stop selection
0 to 100s,
1000 to 1100s,
8888, 9999
0.1s 9999 157 250 3A BA 2 
251 Output phase loss protection selection 0, 1 1 1 190 251 3B BB 2
Life diagnosis
255 Life alarm status display (0 to 15) 1 0 214 255 3F BF 2 
256 Inrush current limit circuit life display (0 to 100%) 1% 100% 214 256 40 C0 2
257 Control circuit capacitor life display (0 to 100%) 1% 100% 214 257 41 C1 2 
258 Main circuit capacitor life display (0 to 100%) 1% 100% 214 258 42 C2 2
259 Main circuit capacitor life measuring 0, 1 (2, 3, 8, 9) 1 0 214 259 43 C3 2 
Power
failure
stop
261 Power failure stop selection 0, 1, 2 1 0 186 261 45 C5 2
267 Parameter for manufacturer setting. Do not set. 267 Parameter for manufacturer setting. Do not set.
268 Monitor decimal digits selection 0, 1, 9999 1 9999 176 268 4C CC 2
269 Parameter for manufacturer setting. Do not set. 269 Parameter for manufacturer setting. Do not set.
270 Stop-on contact control selection 0, 1 1 0 158 270 4E CE 2
Stop-on
contact
control
275
Stop-on contact excitation current low-
speed multiplying factor
0 to 300%, 9999 0.1% 9999 158
275 53 D3 2 
276
PWM carrier frequency at stop-on
contact
0 to 9, 9999 1 9999 158 276 54 D4 2
277
Stall prevention operation current
switchover
0, 1 1 0 120 277 55 D5 2 
Brake sequence
function
278 Brake opening frequency 0 to 30Hz 0.01Hz 3Hz 160 278 56 D6 2
279 Brake opening current 0 to 200% 0.1% 130% 160 279 57 D7 2 
280 Brake opening current detection time 0 to 2s 0.1s 0.3s 160 280 58 D8 2
281 Brake operation time at start 0 to 5s 0.1s 0.3s 160 281 59 D9 2 
282 Brake operation frequency 0 to 30Hz 0.01Hz 6Hz 160 282 5A DA 2
283 Brake operation time at stop 0 to 5s 0.1s 0.3s 160 283 5B DB 2 
Droop
control
286 Droop gain 0 to 100% 0.1% 0% 210 286 5E DE 2
287 Droop filter time constant 0 to 1s 0.01s 0.3s 210 287 5F DF 2 
292 Automatic acceleration/deceleration 0, 1, 7, 8, 11 1 0 140 292 64 E4 2
293
Acceleration/deceleration separate
selection
0 to 2 1 0 140 293 65 E5 2 
295 Magnitude of frequency change setting 0, 0.01, 0.1, 1, 10 0.01 0 226 295 67 E7 2
Password
function
296 Password lock level
0 to 6, 99, 100 to 106,
199, 9999
1 9999 199 296 68 E8 2 
297 Password lock/unlock
(0 to 5), 1000 to 9998,
9999
1 9999 199 297 69 E9 2 
298 Frequency search gain 0 to 32767, 9999 1 9999 180 298 6A EA 2 
299
Rotation direction detection selection
at restarting
0, 1, 9999 1 0 180 299 6B EB 2
Digital output
313 RX9 function selection
0, 1, 3, 4, 7, 8, 11 to 16,
20, 25, 26, 46, 47, 64,
68, 80, 81
90, 91, 93,
95, 96, 98, 99, 100, 101,
103, 104, 107, 108,
111 to 116, 120, 125,
126, 146, 147, 164, 168,
180
181 190, 191, 193,
195, 196, 198, 199,
9999
1 9999 167 313 0D 8D 3 
314 RXA function selection 1 9999 167 314 0E 8E 3
315 RXB function selection 1 9999 167 315 0F 8F 3 
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Instruction Code Control Mode-based Correspondence Parameter
Read Write Extended Clear
All clear
V/F
V/F
V/F
AD
MFVC
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC
GP
MFVC