Mitsubishi Electric FR-A720-0.4K Specifications Page 56

  • Download
  • Add to my manuals
  • Print
  • Page
    / 103
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 55
59
When setting parameters, refer to the instruction manual (applied) and understand instructions.
You can select the second (third) function using RT (X9) signal.
You can also set the RT (X9) signal operation condition (reflection time).
Funtions which can be set as second and third function
Parameter which can be read from the operation panel and
parameter unit can be restricted.
The inverter is set to display all parameters with initial setting.
User group function (Pr.160, Pr.172 to Pr.174)
The user group function is designed to display only the
parameters necessary for setting.
From among all parameters, a maximum of 16 parameters can be
registered in the user group. When "1" is set in Pr.160 , only
parameters registered in the user group can be accessed for
reading and writing. (The parameters not registered in the user
group can not be read.)
To set a parameter in the user group, set its parameter number in
Pr.173.
To delete a parameter from the user group, set its parameter
number in Pr.174 . To batch-delete the registered parameters, set
Pr.172 to "9999".
You can use the setting dial of the operation panel (FR-DU07) like
a potentiometer to perform operation.
The key operation of the operation panel can be disabled.
Selection of action conditions of the second
function signal (RT) and third function signal (X9)
Pr.155
RT signal reflection condition selection
Pr.155 Setting Description
0 (initial value)
These functions are immediately made valid
with on of the RT signal.
10
These functions are valid only during the RT
signal is on and constant speed operation.
(invalid during acceleration/deceleration)
Function
First
Function
Parameter
Second
Function
Parameter
Third
Function
Parameter
Torque boost
Pr.0 Pr.46 Pr.112
Base frequency
Pr.3 Pr.47 Pr.113
Acceleration time
Pr.7 Pr.44 Pr.110
Deceleration time
Pr.8 Pr.44, Pr.45 Pr.110, Pr.111
Electronic thermal
O/L relay
Pr. 9 Pr.51
Stall prevention
Pr.22 Pr.48, Pr.49 Pr.114, Pr.115
Applied motor
Pr. 71 Pr. 450
Motor constants
Pr.80 to Pr.84,
Pr.89
Pr.90 to Pr.94,
Pr.96
Pr.453 to Pr.457
Pr.569,
Pr.458 to Pr.462,
Pr.463
Motor control method
Pr.800 Pr.451
Analog input filter
Pr.822, Pr.826 Pr.832, Pr.836
Gain adjustment
Pr.820, Pr.821,
Pr.824, Pr.825
Pr.830, Pr.831,
Pr.834, Pr.835
Speed detection filter
Pr.823 Pr.833
156, 157
Refer to the section about Pr.22.
158
Refer to the section about Pr.52.
159
Refer to the section about Pr.135.
User group function
Pr.160 User group read selection Pr.172
User group registered display/batch clear
Pr.173 User group registration Pr.174 User group clear
Pr.160 Setting Description
0
(initial value)
All parameters can be displayed.
1
Only the parameters registered in the user group can
be displayed.
9999
Only the simple mode parameters can be displayed.
Pr.
155
P
r.
Pr.
Pr.
Pr.
Pr.
Pr.
Pr.
Pr.
160, 172 to 174
P
r.
Operation selection of the operation panel
Pr.161 Frequency setting/key lock operation selection
Pr.161 Setting Description
0 (initial value)
Setting dial frequency setting mode
Key lock mode
invalid
1
Setting dial potentiometer mode
10
Setting dial frequency setting mode
Key lock mode
valid
11
Setting dial potentiometer mode
162 to 165
Refer to the section about Pr.57.
166, 167
Refer to the section about Pr.150.
168, 169
Parameter for manufacturer setting. Do not set.
170, 171
Refer to the section about Pr.52.
172 to 174
Refer to the section about Pr.160.
Pr.
161
P
r.
Pr.
Pr.
Pr.
Pr.
Pr.
Pr.
Pr.
Pr.
Pr.
Pr.
Page view 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 102 103

Comments to this Manuals