1. FUNCTIONS AND CONFIGURATION
1 - 1
1. FUNCTIONS AND CONFIGURATION
POINT
CC-Link IE Field Network communication function is available for the MR-J3-_T
servo amplifiers of which software version is B0 or above.
1.1 Summary
This instruction manual explains about MR-J3-T10 CC-Link IE Field Network interface unit. Refer to MR-J3-
_T Servo Amplifier Instruction Manual for the information not given in this manual.
Always use MR-J3-T10 with an MR-J3-_T. MR-J3-T10 enables an MR-J3-_T to connect to the CC-Link IE
Field Network by being attached to the MR-J3-_T.
The CC-Link IE Field Network communication function is exclusive of the CC-Link communication function. It
cannot be used with the CC-Link communication function at the same time.
1.2 System configuration
CN2
MR-J3-_T
CN2
CN10B
CN2
CN10B
CN10A
CNP3
CN10A
CNP3
CN10B
CN10A
CNP3
Controller
Slave
MR-J3-T10 MR-J3-_T MR-J3-T10MR-J3-_T MR-J3-T10
Master
1.3 Standard specifications
Model MR-J3-T10
Voltage 5 V DC (supplied from the servo amplifier)
Control circuit
power supply
Rated current [A] 0.8
I/O interfaces CC-Link IE Field Network interface
Number of communication ports 2 (CN10A connector/CN10B connector)
Structure Natural-cooling, open (IP rating: IP 00)
Operation
0 °C to 55 °C (non-freezing)
Ambient
temperature
Storage
-20 °C to 65 °C (non-freezing)
Operation
Ambient
humidity
Storage
90 %RH or less (non-condensing)
Ambience Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude 1000 m or less above sea level
Environment
Vibration resistance 5.9 m/s
2
at 10 Hz to 55 Hz (X, Y and Z axes)
Mass [g] 150