3.2 Operation Panel
OPERATION/CONTROL
46
3.2 Operation Panel
With the operation panel (FR-DU04), you can set the running frequency, monitor the operation command
display, set parameters, display an error, and copy parameters.
3.2.1 Names and functions of the operation panel (FR-DU04)
Display
LED
×
4 digits
Mode key
Set key
Unit indication
!
Hz (frequency)
!
A (current)
!
V (voltage)
Operation status indication
Forward rotation key
Stop and reset key
FR-DU04
Hz
A
V
MON EXT PU
CONTROL PANEL
FWD
MODE
SET
REV FWD
STOP
RESET
REV
Up-down Key
Reverse rotation key
Key indications
Key Description
MODE
key
You can select the operation mode or setting mode.
SET
key
You can determine the frequency and parameter setting.
key
Used to increase or decrease the running frequency consecutively. Hold down this key to change the
frequency.
Press this key in the setting mode to change the parameter setting consecutively.
FWD
key
Used to give a forward rotation command.
REV
key
Used to give a reverse rotation command.
STOP
RESET
key
Used to stop operation.
Used to reset the inverter when its output is stopped by the protective function activated (major fault).
Unit indications, operating status indications
Indication Description
Hz Lit to indicate the frequency.
A Lit to indicate the current.
V Lit to indicate the voltage.
MON Lit in the monitor display mode.
PU Lit in the PU operation mode.
EXT Lit in the external operation mode.
FWD Flickers to indicate forward rotation.
REV Flickers to indicate reverse rotation.
3.2.2 Monitor display changed by pressing the
MODE
key
MODE MODE MODE MODE
MODE
#
Help mode
#
Monitoring mode
#
Parameter setting mode
#
Operation mode
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
#
Frequency setting mode
(Note)
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
Note: The frequency setting mode is displayed only in the PU operation mode.