4.1 Parameter List
PARAMETERS
60
4 PARAMETERS
4.1 Parameter List
4.1.1 Parameter list
All parameters available when the Pr. 160 "user group read selection" value is "0" are indicated below.
The parameters available when the Pr. 160 value is "9999" (Simple mode parameter) are marked in the
Parameter Number column with a circle (
$
).
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Setting
Increments
Factory
Setting
EC
Version
Refer
To
Page:
Cust-
omer
Set-
ting
$
0 Torque boost 0 to 30% 0.1%
6%/4%/3%
/2%
(Note 4)
66
$
1 Maximum frequency 0 to 120Hz 0.01Hz 120Hz 67
$
2 Minimum frequency 0 to 120Hz 0.01Hz 0Hz 67
$
3 Base frequency 0 to 120Hz 0.01Hz
60Hz
50Hz
68
$
4 Multi-speed setting (high speed) 0 to 120Hz 0.01Hz 60Hz 69
$
5 Multi-speed setting (middle speed) 0 to 120Hz 0.01Hz 30Hz 69
$
6 Multi-speed setting (low speed) 0 to 120Hz 0.01Hz 10Hz 69
$
7 Acceleration time
0 to 3600 s/
0 to 360 s
0.1 s/
0.01 s
5 s/15 s
(Note 1)
70
$
8 Deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/
0.01 s
10 s/30 s
(Note 1)
70
Basic functions
$
9 Electronic thermal O/L relay 0 to 500A 0.01A
Rated
output
current
71
$
10 DC injection brake operation frequency 0 to 120Hz, 9999 0.01Hz 3Hz 72
$
11 DC injection brake operation time 0 to 10 s, 8888 0.1 s 0.5 s 72
$
12 DC injection brake voltage 0 to 30% 0.1%
4%/2%
(Note 1)
72
$
13 Starting frequency 0 to 60Hz 0.01Hz 0.5Hz 73
$
14 Load pattern selection 0, 1 1 1 74
15 Jog frequency 0 to 120Hz 0.01Hz 5Hz 75
16 Jog acceleration/deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/
0.01 s
0.5 s 75
17 MRS input selection 0,2 1 0 76
$
19 Base frequency voltage 0 to 1000V, 8888, 9999 0.1V
9999
8888
68
20
Acceleration/deceleration reference
frequency
1 to 120Hz 0.01Hz
60Hz
50Hz
70
21
Acceleration/deceleration time
increments
0,1 1 0 70
22 Stall prevention operation level 0 to 150%, 9999 0.1% 120% 77
23
Stall prevention operation level
compensation factor at double speed
0 to 200%, 9999 0.1% 9999 77
24 Multi-speed setting (speed 4) 0 to 120Hz, 9999 0.01Hz 9999 69
25 Multi-speed setting (speed 5) 0 to 120Hz, 9999 0.01Hz 9999 69
26 Multi-speed setting (speed 6) 0 to 120Hz, 9999 0.01Hz 9999 69
27 Multi-speed setting (speed 7) 0 to 120Hz, 9999 0.01Hz 9999 69
28 Multi-speed input compensation 0, 1 1 0 78
29 Acceleration/deceleration pattern 0, 1, 2, 3 1 0 79
30 Regenerative function selection 0, 2 1 0 80
31 Frequency jump 1A 0 to 120Hz, 9999 0.01Hz 9999 81
32 Frequency jump 1B 0 to 120Hz, 9999 0.01Hz 9999 81
33 Frequency jump 2A 0 to 120Hz, 9999 0.01Hz 9999 81
34 Frequency jump 2B 0 to 120Hz, 9999 0.01Hz 9999 81
35 Frequency jump 3A 0 to 120Hz, 9999 0.01Hz 9999 81
36 Frequency jump 3B 0 to 120Hz, 9999 0.01Hz 9999 81
37 Speed display 0,1 to 9998 1 0 82
38 Automatic torque boost 0 to 200 0.1% 0 83
Standard operation functions
39
Automatic torque boost operation
starting current
0 to 500 0.01A 0 83