Mitsubishi Electric PC36 Instruction Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 50
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
3. PARAMETERS
3 - 6
3.4.2 Detail description
POINT
The parameter names of [Pr. PD25] is not displayed with the following versions
of MR Configurator/MR Configurator2. However, this setting value is
changeable. Follow the instructions in this Instruction Manual to set a value.
MRZJW3-SETUP221E: software version C3 or below
SW1DNC-MRC2-E: software version 1.09K or below
No. Symbol Name and function
Initial
value
Setting
range
Unit
PD25 A8DT [AL. 8D CC-Link IE communication error] detection time
Selecting the [AL. 8D] detection time in [Pr. PC50] activates the time setting of
[AL. 8D].
It is 10 ms when [Pr. PC50] = "0".
Convert a decimal value to a hexadecimal value for input.
The setting range is up to 1000 ms. A set value is limited within the setting
range.
For example) If "03E8h" is set, the set value becomes 1000 ms.
The converted decimal value of "1388h" is 10000 ms, but it is
limited to 1000 ms, which is the upper limit of the setting range.
0000h 0000h
to
03E8h
ms
CAUTION
If [AL. 8D CC-Link IE
communication error] does not
have to be detected, use the
communication time-out setting in
the initial setting. When you
change the setting value, do not
set an unnecessarily long time
period. Doing so interferes swift
stop operation at an occurrence of
[AL. 8D CC-Link IE
communication error].