Mitsubishi Electric FR-E540 Instruction Manual Page 87

  • Download
  • Add to my manuals
  • Print
  • Page
    / 217
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 86
PARAMETERS
74
4.2.9 Load pattern selection (Pr. 14)
Pr. 14 "load pattern selection"
You can select the optimum output characteristic (V/F characteristic) for the application and load
characteristics.
Setting "4" (energy-saving mode) or "9" (optimum excitation control mode) in Pr. 60 "intelligent mode
selection" changes the output voltage.
Parameter
Number
Factory
Setting
Setting Range
14 1 0, 1
100%
Pr.14=0
Output frequency (Hz)
For constant-torque loads
(e.g. conveyor, cart)
Output
voltage
Base frequency
Output frequency (Hz)
For variable-torque loads
(Fan, pump)
100%
Base frequency
Pr.14=1
Output
voltage
Setting Output Characteristics Application
0 For constant-torque load Conveyor, cart, etc.
1 For variable-torque load Fan, pump
Pr. 0 "torque boost"
Pr. 60 " intelligent mode selection"
Pr. 180 to Pr. 186
(input terminal function selection)
Related parameters
Page view 86
1 2 ... 82 83 84 85 86 87 88 89 90 91 92 ... 216 217

Comments to this Manuals

No comments