Inspection Item
6
PRECAUTIONS FOR MAINTENANCE AND INSPECTION
6.1.5 Checking the inverter and converter modules
<Preparation>
(1) Disconnect the external power supply cables (R/L1, S/L2, T/L3) and motor cables (U, V, W).
(2) Prepare a tester. (Use 100 range.)
<Checking method>
Change the polarity of the tester alternately at the inverter terminals R/L1, S/L2, T/L3, U, V, W, P/+ and N/, and
check for continuity.
<Module device numbers and terminals to be checked>
(Assumes the use of an analog meter.)
6.1.6 Cleaning
Always run the inverter in a clean status.
When cleaning the inverter, gently wipe dirty areas with a soft cloth immersed in neutral detergent or ethanol.
CAUTION
1. Before measurement, check that the smoothing capacitor is discharged.
2. At the time of discontinuity, due to the smothing capacitor, the tester may not indicate . At the time of continuity, the
measured value is several to several ten's-of ohms depending on the module type, circuit tester type, etc. If all measured
values are almost the same, the modules are without fault.
Tester
Polarity
Measured
Value
Tester
Polarity
Measured
Value
Converter module
D1
R/L1 P/+ Discontinuity
D4
R/L1 N/ Continuity
P/+ R/L1 Continuity N/ R/L1 Discontinuity
D2
S/L2 P/+ Discontinuity
D5
S/L2 N/ Continuity
P/+ S/L2 Continuity N/ S/L2 Discontinuity
D3
T/L3 P/+ Discontinuity
D6
T/L3 N/ Continuity
P/+ T/L3 Continuity N/ T/L3 Discontinuity
Inverter module
TR1
UP/+ Discontinuity
TR4
UN/ Continuity
P/+ U Continuity N/ U Discontinuity
TR3
VP/+ Discontinuity
TR6
VN/ Continuity
P/+ V Continuity N/ V Discontinuity
TR5
WP/+ Discontinuity
TR2
WN/ Continuity
P/+ W Continuity N/ W Discontinuity
CAUTION
Do not use solvent, such as acetone, benzene, toluene and alcohol, as they will cause the inverter surface paint to peel off.
Converter module Inverter module
D1 D2 D3
D4 D5 D6
TR1 TR3 TR5
TR4 TR6 TR2
U
V
W
R/L1
S/L2
T/L3
C
P/+
N/