Page view 125
121
Extended parameters
Extended parameter list
Adjustable 5 points V/F
100
V/F1(first
frequency)
0.01Hz 9999
0 to 400Hz,
9999
Set each points (frequency, voltage) of V/
F pattern.
9999: No V/F setting

101
V/F1(first frequency
voltage)
0.1V 0V 0 to 1000V

102
V/F2(second
frequency)
0.01Hz 9999
0 to 400Hz,
9999

103
V/F2(second
frequency voltage)
0.1V 0V 0 to 1000V

104
V/F3(third
frequency)
0.01Hz 9999
0 to 400Hz,
9999

105
V/F3(third
frequency voltage)
0.1V 0V 0 to 1000V

106
V/F4(fourth
frequency)
0.01Hz 9999
0 to 400Hz,
9999

107
V/F4(fourth
frequency voltage)
0.1V 0V 0 to 1000V

108
V/F5(fifth
frequency)
0.01Hz 9999
0 to 400Hz,
9999

109
V/F5(fifth frequency
voltage)
0.1V 0V 0 to 1000V

71
Refer to page 119.
Func
t
ion
Parameter
Name
Incre
ments
Initial
Value
Range Description
Param
eter
copy
Param
eter
clear
All
param
eter
clear
Related
parameters
: enabled
× : disabled