42
Operation by the start command from
the operation panel (PU operation mode)
REMARKS
Pr. 184 AU terminal function selection must be set to "4" (AU signal) (initial value). (Refer to the Instruction Manual (applied).)
Change the frequency (60Hz) at the maximum value of potentiometer (at 20mA)
Adjust the frequency in Pr. 126 Terminal 4 frequency setting gain frequency. (Refer to page 50.)
Change the frequency (0Hz) at the minimum value of potentiometer (at 4mA)
Adjust the frequency in calibration parameter C5 Terminal 4 frequency setting bias frequency. (Refer to
the Instruction Manual (applied).)
Stop
Flickering
DisplayOperation
10.
Deceleration
Perform 4mA input.
The frequency value on the indication
decreases according to Pr. 8 Deceleration time
until 0.00Hz is displayed and the operation
status indication of FWD or REV flickers.
The motor stops.
11.
Stop
Press .
FWD or REV of the operation status indication
turns off.
Output of the
adjustment meter
(4 to 20mADC)
Output of the
adjustment meter
(4 to 20mADC)
9.
Acceleration constant speed
Perform 20mA input.
The frequency value on the indication increases
according to Pr. 7 Acceleration time until 60.00Hz
is displayed.