5 - 7
5 TRIAL OPERATION AND ADJUSTMENT
5.3 Operating System Software Installation Procedure
The operating system software must be installed to the Motion CPU module by using
the peripheral device and programming software package.
End
Start installation
Open the cover at the front of the
Motion CPU and turn ON the install
switch.
Turn ON the Motion CPU power supply.
Refer to Section 2.4.1(3) for install switch.
RUN/STOP key switch is ignored.
Install of operating system software
according to the programming software
package instructions.
After installation, turn OFF the Motion
CPU power supply.
Turn OFF the install switch and close
the cover at the front of the Motion
CPU.
POINTS
(1) The operating system software was not installed at the time of Motion CPU
module purchase. Be sure to install the operating system software to be used
before a system start.
(2) Even if the operating system software is installed, the positioning data and
servo programs written in the Motion CPU module does not be rewritten.
(3) Do not turn off the power supply during installation. The Motion CPU module
may break down.
(4) When the operating system software is installed at set the Multiple not installed
Motion CPU modules in one base unit, be sure to turn ON the install switches
of all not installed Motion CPU modules to install.
(Note): If the power supply is turned ON in the state of the install switch OFF
of all not installed Motion CPU modules, it does not operate normally.
Be sure to install the operating system software after system start.