Mitsubishi Electric Q172CPU User Manual Page 49

  • Download
  • Add to my manuals
  • Print
  • Page
    / 234
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 48
2 - 30
2 SYSTEM CONFIGURATION
(4) Basic specifications of Q173CPU(N)/Q172CPU(N)
(a) Module specifications
Item Q173CPUN Q173CPUN-T Q173CPU Q172CPUN Q172CPUN-T Q172CPU
Teaching unit —— Usable —— —— Usable ——
Internal current
consumption(5VDC) [A]
1.25 1.56
(Note)
1.75 1.14 1.45
(Note)
1.62
Mass [kg] 0.23 0.24 0.22 0.22 0.23 0.21
Exterior dimensions
[mm(inch)]
98(3.86)(H) 27.4(1.08)(W)
114.3(4.50)(D)
118(4.65)(H)
27.4(1.08)(W)
89.3(3.52)(D)
98(3.86)(H)
27.4(1.08)(W)
114.3(4.50)(D)
118(4.65)(H)
27.4(1.08)(W)
89.3(3.52)(D)
(Note) : Current consumption 0.26[A] of the teaching unit is included.
(5) SV13/22 Motion control specifications/performance specifications
(a) Motion control specifications
Item Q173CPUN(-T) Q173CPU Q172CPUN(-T) Q172CPU
Number of control axes Up to 32 axes Up to 8 axes
SV13
0.88ms/ 1 to 8 axes
1.77ms/ 9 to 16 axes
3.55ms/17 to 32 axes
0.88ms/1 to 8 axes
Operation cycle
(default)
SV22
0.88ms/ 1 to 4 axes
1.77ms/ 5 to 12 axes
3.55ms/13 to 24 axes
7.11ms/25 to 32 axes
0.88ms/1 to 4 axes
1.77ms/5 to 8 axes
Interpolation functions
Linear interpolation (Up to 4 axes), Circular interpolation (2 axes),
Helical interpolation (3 axes)
Control modes
PTP(Point to Point) control, Speed control, Speed-position control, Fixed-pitch feed,
Constant speed control, Position follow-up control, Speed switching control,
High-speed oscillation control, Synchronous control (SV22)
Acceleration/
deceleration control
Automatic trapezoidal acceleration/deceleration,
S-curve acceleration/deceleration
Compensation Backlash compensation, Electronic gear
Programming language Motion SFC, dedicated instruction, Mechanical support language (SV22)
Servo program capacity 14k steps
Number of positioning
points
3200 points
(Positioning data can be designated indirectly)
Programming tool IBM PC/AT
Peripheral I/F USB/RS-232/SSCNET
Teaching operation
function
Provided (Q173CPUN-T/Q172CPUN-T, SV13 use)
Home position return
function
Proximity dog type (2 types), Count type (3 types), Data set type (2 types), Dog cradle type,
Stopper type(2 types), Limit switch combined type
(Home position return re-try function provided, home position shift function provided)
JOG operation function Provided
Manual pulse generator
operation function
Possible to connect 3 modules
Page view 48